thanks for your suggestion Bimr,
The space problem we have is so high that pushed economic troubles in second sight. Anyhow the cost of fines will be higher on the long term.
If I understood right, you suggestion is to make a mixuture of air/ozone and water and make it pas thruogh the UV lamp...
the main problem we are facing is that it is impossoble to use a biological step due to chlorine contamination in influent water.
We already tried with bio-membrane treatment, but was impossible to have the bio stage well working.
In addition to this, there is also an high amount of emulsified...
the main problem we are facing is that it is impossoble to use a biological step due to chlorine contamination in influent water.
We already tried with bio-membrane treatment, but was impossible to have the bio stage well working.
In addition to this, there is also an high amount of emulsified...
Hi Muggle,
Thanks for your interest!
Regarding the additional data you required, please find them here below.
The daily flow rate of WWTP is 100 tons/day.
The water we are treating is a mixusture of wastewaters similar to municipality wastewaters: black, sanitary, laundry, food waste...
Hi,
we are now testing a phisico-chemical sewage treatment plant.
The system is working pretty well on most of pollutants.
The biggest problem we are facing is dissolved BOD reduction. Obtained effluent is at 170 mg/l, while limit is set on 30 mg/l. The BOD reduction along the treatment is 90%...