  1. sb00

    Largest FCC Unit

    Hi folks, does anyone know where is the largest FCC of the world? Is it at Pertamina, Indonesia or Reliance, India? Thanks, -SB
  2. sb00

    Acceptable Hydrotest Pressure Drop

    Hi, any one has any idea about the acceptable rate of loss in bar/min for hydrotest acceptability as per ASME 31.3? Thanks.
  3. sb00

    NPSHR for pregressive cavity pumps

    Hi folks, does API 676 apply to progressive cavity pumps? I want to know it with respect to the cavitation criteria of 3% drop in flow or head. Do progressive cavity pumps also follow same cavitation criteria (for NPSHR calculation) of 3% drop in flow/head? If not, what is the cavitation...
  4. sb00

    Progressive Cavity Pump

    Hi folks, I have to install a Progressive Capacity Pump and I wish to do the motor run test. Now, the problem is that the pump data sheet mentions "Coupling- No, Block-Yes". I believe, this 'block' does the function of the coupling. Does anyone know if I can remove the block (easy or...
  5. sb00

    API 610 NPSHr

    Hi Guys, our cd seems to be corrupted. I need to check if API 610 requirement for NPSH testing (4.3.4.1.3) talks about checking the pressure at 3% head drop or something else? thanks in advance...
  6. sb00

    Can You Spec A Pump with Negative NPSHA/NPSHR

    just wanna add that in the refinery i worked for, we used to store LPG in horton spheres at around 12 barg. It avoids two phase flow thru pumps and keeping LPG at high pressure also minimizes loss due to vaporization.
  7. sb00

    Heat developed in circulating fluid

    Hi guys, I have a vessel with say 100m3 of water at room temp. I have to keep it recirculating with a centrifugal pump of 1MW capacity. I am concerned abt the temp rise of the fluid. The temp rise is only due to the friction losses, rite? So, i should calculate as follows: Electrical power...
  8. sb00

    hydraulic limit of a distillation column

    Hi folks, the limiting conditions in a distillation column are because of limitations on Vapor/Liq ratio- if V/L is very high, the column will go under flooding, if V/L is very low, it will exhibit weeping and so on... Now, I have a serious difference of opinion from two of my colleagues (who...
  9. sb00

    Li-polymer battery

    Hi FOlks, Sorry, I dont belong to this community. So if the questions sounds trivial, forgive me! I want some information about Li-polymer batteries. Is frequent charging a problem for Li-polymer batteries? Is there anything like "overcharging" ? Leaving the battery under charging for...
  10. sb00

    pump alignment

    thnx guys, very informative and helpful as ever!
  11. sb00

    pump alignment

    Hi folks, i was reading some where that pump alignment should be done at the operating temperature. Does it really make much of a difference if say, my operating temperature is below 60 C and i align the pump at 25 C? Thanks... -SB
  12. sb00

    Pump Acceptance Test Standards

    Man, when u can get it for free, why waste money? Afterall, very competitive environment these days! Thnx guys. I have gone to www.pumps.org and also scoured hydraulic institute website. But all have to be purchased! Cronin, is hydrostatic test same as hydrotest? Hydrotest is mandatory for all...
  13. sb00

    Pump Acceptance Test Standards

    Hi folks, where can i find some "free" info on detailed standards for pump acceptance tests? Actually, we normally go for motor checks, ppump performance checks (head, capacity, power, NPSH), logic checks (start/stop, duty/standby), vibration, noise etc... Can anyone tell what other...
  14. sb00

    NRV positioning

    thnx saxon...ur inputs will surely help me resolve my problems.
  15. sb00

    NRV positioning

    oh yes, why didnt it click to me? Thnx guys!
  16. sb00

    NRV positioning

    Hi Guys, I have a set of PIDs with me and it seems the designer has put NRV before discharge valve in all pumps. Dont u think this can be a problem due to thermal expansion of the liquid trapped in between the NRV and the discharge valve (when the discharge valve is closed)? Actually, I have...
  17. sb00

    Air Dryer Design

    thnx guys.....
  18. sb00

    Air Dryer Design

    Actually, I need to know details like: 1) Do we use multiple beds in the same dryer vessel or single beds are sufficient. 2) What type of support shoud I select for my packed beds- I will also need to re-generate it. I just need general information regarding hte design. I f I am unable to...
  19. sb00

    Air Dryer Design

    Hi, where can I get information on how to design an air dryer for instrument air compressor? Thanks, -SB