My Question is,
How are u measuring the Do2 in suction and discharge?
If there are no leaks then the possibility of increase in O2 content at the discharge may be due to the following reason.
1. If you are measuring continously using a sampling system then take care that the sample pressure...
2. Not all horizontal HRSGs have the headers in gas path. I have seen the Heders outside the gas path. A sepearation is made with plate along with accessories to take care that gas doen't escape. The headers are insulated externally.
3. Although it is not mandetory to insulate internally, it is...
For key points:
You have to specify the fuel used (gas or liquid fuel) and approx calorific value.
You have to mention in your specs about Excess air available from GT exhaust and Flue gas temp at GT exhaust.
Specify whether u require a continous pilot or a startup pilot, in case if u use a...