Temp is estimated to be around 650F. Thermal expansion calculated to be about 60". It has BAD written all over it, and we are attempting to sway the client towards another solution. Thanks for your input.
The client wants an 8" steam line installed under a right-of-way from one facility to another. I'm not even sure if it is feasible or not yet and just exploring all aspects of a buried line. The line is proposed to be insulated and cased in at least a 12" casing. I was thinking more of the...
I have a situation where an 8" insulated, cased line will be installed via boring and jacking +/- 600 feet. The pipe will only be accessible where it exits the ground on each end. Can someone recommend which method to look at for cathodic protection?