Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations MintJulep on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Bradley5

    Stamping plans for welded Ibeam building?

    Ron, the guys that are welding these are indeed welding pros with plenty of credentials. As for the purlin attachments, they do weld them to the beam flange, but also add a 6" triangle clip. Just because I have the time right now, I am running some math on the building and I think we can...
  2. Bradley5

    Stamping plans for welded Ibeam building?

    Ron, lol, how right you are engineering comes before building..... Unless you are a backyard bandit. Then you build it on a guess, and make claims about how overbuilt it is.... Regarding the building, 60x100x18, 2:12 pitch, 25ft bays, 15# snow, 20# live, 112 wind ASCE-7. We have plenty of...
  3. Bradley5

    Stamping plans for welded Ibeam building?

    What we are ultimately faced with is a documented, certified welding team that simply does not fully understand structure design. They appear to work off other sealed plans and "rule of thumb". If we go this route, we would ultimately spec all materials, welds, etc, but have some comfort in...
  4. Bradley5

    Stamping plans for welded Ibeam building?

    When I mentioned the steel vendor, they are a separate entity. Only a building material and steel supply house. We've actually bought from them in the past. As for the builder, yes, I mentioned that I may just let him put together a proposal, then evaluate the design to see if it even holds...
  5. Bradley5

    Stamping plans for welded Ibeam building?

    Agreed! The vendor of the steel is a large and reputable company. I think the way we might approach this is evaluate plans as the builder wishes to build it and run load calcs against it to refine and validate it. Probably adding some required structural improvement elements. I do notice...
  6. Bradley5

    Stamping plans for welded Ibeam building?

    Thanks. If we go this route, we would end up being the engineer of record. However, though we can run load calcs, there are many different ways to build such a building and we have no experience in such animals. I guess we might want to sniff around for any sealed plans for comparable...
  7. Bradley5

    Stamping plans for welded Ibeam building?

    We are looking to construct a building for ourselves and was leaning towards a PEMB building but delays from manufacturers are creating some issues. We are in talks with a company that basically uses off-the-shelf beams, cut and weld onsite. I'm simply baffled how they do this with no...
  8. Bradley5

    Optimizing insulation methods in PEMB building.

    LOL, you nailed it with FEMA! Regarding building science, yes, I have honestly wanted to have that conversation with someone that truly understands this challenge. Correct about the whole vapor/air barrier deal. I really do NOT want a vapor seal on the top side, I just want a better air...
  9. Bradley5

    Optimizing insulation methods in PEMB building.

    We are working on designs of a couple buildings, mostly used for manufacturing so mostly no interior finishes other than the insulation facing. What is common is the "super saver" method, which is decent, but I am questioning the need and extra expense of the poly liner as opposed to just...
  10. Bradley5

    PEMB buildings from China? Engineering?

    AND to make this more interesting, it appears the pricing is going to be comparable, or even more expensive. IE, at least with that company, zero reason or incentive to even consider such a building with all the potential engineering questions.
  11. Bradley5

    PEMB buildings from China? Engineering?

    I would be curious how that is purchased and evaluated? Do you get foreign calcs? Are these Chinese or something more substantial like German? I think it's one thing when bringing in a high quality item. Quite another knowing full well a foreign purchase is a cost cutting tactic. As I...
  12. Bradley5

    PEMB buildings from China? Engineering?

    Oh you 100% nailed that! Dime a dozen of the people that say "we just need this stamped", like "oh, no biggy, here ya go, I now own a lifetime of risk". Years back we were looking to use some steel fabricated roof trusses. Says "engineered" right on them...lmao. We ended up modeling them to...
  13. Bradley5

    PEMB buildings from China? Engineering?

    I would say that is why I am here asking. Trying to better understand how common this is, if at all.
  14. Bradley5

    PEMB buildings from China? Engineering?

    We are working on a couple projects with PEMB buildings. We primarily have only done the engineered footing work for such buildings on the past. A guy in the office reached out to a building supplier to find out they drop ship the building kit right from China? I am now very curious if this...
  15. Bradley5

    IFC IBC fire codes and occupancy.

    I wasn't certain which section to put this but we are assisting in design and construction of a multi use building in a rural area. The building size is 15,000sf, prefab steel building, free span single story, 20' tall. Because of the rural area and desire from owners, avoiding a sprinkler...
  16. Bradley5

    Obtaining a GC license? Anyone here done that?

    Oh yes, it would seem I need to test with my state, then pay my COUNTY an entire grand and that lasts for 2yrs! Scam? lol What I want to know is if the test a reciprocal with other states and such. I think my county wants to be like CA the FL. Paper and fees to mow your own lawn. I am...
  17. Bradley5

    Obtaining a GC license? Anyone here done that?

    Honestly, I could not find any place to discuss this so figured I would run with my love language. I am looking to obtain my GC license, purely to satisfy some red tape locally. However, if I am going to go take a test, I'd really like to know more about all of this and how it carries between...
  18. Bradley5

    Help selecting a low pressure, higher volume air blower.

    We need a blower that serves a simple purpose...to blow out some liquid lines when needed. We have determined that 5-10cfm and 30 psi is sufficient. We might normally use an air compressor but need the ability to use gasoline powered for this. I was originally looking at regenerative...

Part and Inventory Search

Back
Top