Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations MintJulep on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. herreraam1

    Hello, Guys. I am new here and have

    Thank you all, guys for your fast reply. Your comments made me to see it better.
  2. herreraam1

    Hello, Guys. I am new here and have

    Thank you guys for your attention. Here's a picture of the mentioned branch connection. The pipe run is 26" grade X-52 and the branch is 6" STD, grade B. This is a valve station that the customer required to be constructed in accordance with ANSI B31.3 since it is inside a cryogenic complex. The...
  3. herreraam1

    Hello, Guys. I am new here and have

    Hi, Pennpiper. As I wrote, we are in the pre-commissioning stage, so the pipeline is already constructed. The run pipe is 26" and 0,4382" thick. The branch is 6" STD. The reinforcing pad is the same material and thickness as the run pipe, in accordance with the available records. Thank you for...
  4. herreraam1

    Hello, Guys. I am new here and have

    Hello, Guys. I am new here and have, hope so, a silly question. In a branch connection for a pipeline that I am checking for pre-commissioning I found that the run pipe is API 5L, X-52 and the branch pipe is API 5L, grade B. Looking at the construction code, ANSI B31.3, and associated...