HTRI program runs on allowable entrainment of < 2% wt Entrainment has 2 major is the adverse effects:
1.Excessive pressure drop
2.Effect on bottom tray efficiency,of the vapor is part of a reboiler circuit in distiilation..etc
Up to 5% wt vapor is allowed as long as your DelP is <0.2 psi/100...
Hi Lovison,
VOC-Volatile Organic Compounds,a big EPA concern..
Can you please elaborate on the Oil-Mist technology ,so we can proceed with abating oil escape into the atmosphere
Regards,
Hi moistureman,
A good source for formulations (Bennet's-Chemical Formulation Handbook..comprising many volumes )a good reference library should have a copy..
Otherwise all ingredient suppliers ,will be happy to provide the formulation,and production technique .
Regards,
Hi Hogweed,
Generally,operating manuals are prepared by the contractor
(party that design and build the plant) to the client(party who owns the plant..On the other hand in order to prepare the operating manual,a combination of vendors catologue information (in your case : vendors of loading...
Hi Falcon 03,
In a traditional refinery flash points are taken care off in the side strippers,whereas pour points are related to end points,for kerosene the higher the end point,the higher the pour(freeze) point..and also depends on the crude type and paraffin content.
Having said ,the model...
Hi DeeZee,
A good injection point could be upsream of the Effluent Water/Inlet Water heat exchanger,and work to maintain a PH(6-8.5),your PH meter,and sampling point can be after the cooler.
Regards,
Hi PaulMinchin,
I agree the UA will change ,due an a change in the U value
which is approximately of 1/U = 1/hi +1/ho + t/k
hi = tubes-inside heat transfer coefficient
ho = tubes-outside heat transfer coefficient
t = tube wall thickness, k= tube metal thermal coductivity
And the main...
Hi Quimicaucfa,
I think the Hastelloys can handle acid environment well..You better consult Nalco Handbook,or The Hedndrix Group web site at (www.hghouston.com/material.html)
Regards,
Whylie
SL1000,
Hi..Depending on your system configuration..you may use a local nearby condensate horizontal drum with good residence time and vapour recycle..or rearrange your steam traps..I suggest you look up (Armstrong Steam University)..veru helpful tips ..Also Spirax-Sarco..selection program,can...
Gentlemen,
I have come across the simplified equation,based on (Pipelines Rules of Thumb) by Gulf Publishing 1978:
P= 0.8 x W x V
Where P surge pressure psi
W Fluid density lb/cu.ft
V Velocity change ft/sec
This equation gives < 5% deviation from the standard equation
Try...
Hi BIB,
Stack fans have low delivery pressure,but high volume..
I suggest you contact (www.twincity.com) or any other manufacturer,you can find in (www.Thomasregister.com),or at (www.askache.com)
Regards,
Whylie
Hi Booker,
I suggest you contact (www.Nashpumps.com)..if you fail..I have there basic catalogue,may be I can help later
Regards,
Whylie (wayil@hotmail.com)
HI 1080847,
A flash separator for a liquid at it's bubble point,can be worked by putting a PRV (pressure reduction valve) up stream of the separator,at which point you will have Two phase going into the separator..
Email me the composition and I will send you the results..
Ofcourse,it will...