  1. djoko

    high SO2 emission

    hi, I have two different boilers, namely B 6203 and B 1104. B 6203 is a dual burner system, can use fuel oil or natural gas, while B 1104 is can only fuel oil. Fuel oil used on those two boilers is the same, a marine fuel oil (MFO) with viscocity 15,21 cst (on 100 degree Celcius). When used...
  2. djoko

    pH problem on cooling tower

    stonecold, the corrotion rate made me worried..corrotion rate for carbon steel now is 3.49 mpy, usually i got 0.5 mpy. i can't isolate the HE, the only one way is to stop the cooling water system. 25362, we usually check the M alkalinity, it is 50 ppm. before n after the pH decreasing, the M...
  3. djoko

    pH problem on cooling tower

    hi, I have a problem with the pH of cooling tower at ammnonium sulfate (ZA) plant. The normal operation is 7.3-7.8. The make up water is 7.8. Starting from december 25th, the pH is decreasing until 6. There is an online pH analyzer that monitoring pH and a sulfuric acid pump that will work if...
  4. djoko

    cycle number

    dc, thanks for your comment. quark, i got 6 from silica in boiler water/silica in boiler feed water (0.6/0.1). 10 ppm is the maximum silica permitted in boiler water, not the actual silica in boiler water. sorry for the long reply, djoko
  5. djoko

    cycle number

    Hi, Can we calculate the cycle number of boiler based on conductivity? If I calculate it based on Silika content, the cylce number of my boiler with P 35 kg/cm2 only 6. SiO2 inlet 0.1 ppm, silica in boiler water 0.6 ppm. the maximum silica permitted in boiler water is 10 ppm. I think that the...
  6. djoko

    Aluminum triFluoride trihydrate heat capacity

    sae79... i mean AlF3.3H2O aluminum fluoride trihydrate. sorry for the wrong name and thank you for your info. djoko
  7. djoko

    Aluminum triFluoride trihydrate heat capacity

    do anybody know where i can find that?? thanks
  8. djoko

    fluid pipe temperature, insulated and not

    TD2K.. thanks for your advice.I'll begin my calculation.. pmover.. I read from PID, the insulation is needed for heat recovery, not for personal protection. The vertical pipe is about 2 m from stairs up to the tower. There is no problem with the pump. Actually, the main problem is the high CO2...
  9. djoko

    fluid pipe temperature, insulated and not

    hi.. I have a CO2 stripping tower in my ammonia plant.there is a quench water pipe taken from the middle of the tower (at about 60 m from the ground) that will be pumped and cooled by PHE and then back to the top of the tower. The temperature of the quench water out of tower is about 102 C(it's...
  10. djoko

    heat of reaction NH3 with H2O

    hi.. do anybody knows the heat of reaction released from this reaction at 298 K: NH3 (l) + H2O (l) --> NH4OH I know that NH4OH is not a stable condition,will be decomposized and NH3 n H2O are formed.I am trying to calculate from the heat of formation (Hf) every component but i got some problem...