Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. nd0586

    Splices to long span portal frame rafters

    Thanks All! CivEng80 - I'd be more worried about the stiffness throwing the plastic hinge hierarchy, not the capacity. Say you got a couple of degrees slip out of the splice - wouldn't that throw your calcs? Or if the splice was significantly stiffer that the rest of the section, again that...
  2. nd0586

    Splices to long span portal frame rafters

    Thanks for the response! I understand that it is normal practice; however do you make any design allowances for it, or would you be happy for a continuous rafter in a portal frame designed to 100% utilisation (more or less...) to have a splice put in it without any further checks?
  3. nd0586

    Splices to long span portal frame rafters

    Hi all, I have designed a 20m bay portal structure which is currently about to go into fabrication. 20m rafters can be transported to site, but the steel fabricators have requested a splice in the rafters so that they can store them more easily in their yard. The rafters have been designed...
  4. nd0586

    Thermal Movement in Portal Frames

    Thanks! I'll have a read through.
  5. nd0586

    Thermal Movement in Portal Frames

    Thanks for your answers! If my cladding is designed to take the thermal movement from the steelwork, and the portal frames are not stiff enough to cause any locked in stresses, then if i design the columns for the resulting out of verticality would that not be sufficient? I agree that a...
  6. nd0586

    Thermal Movement in Portal Frames

    Thanks for your reply - that's good to know! When I said 9x20m though I wasn't very clear - I meant 9 bays in a row i.e. 180m long in the direction of the portals (by around 220 m in the other direction, but bracing in that direction is another topic...) - is it still acceptable to just impose...
  7. nd0586

    Thermal Movement in Portal Frames

    Hi there, I've been using eng tips as a resource for a while, but this is the first time i haven't found my question already answered in another thread! I'm designing a large (9x20m bays) portal frame, and the software that I'm using to model the frame doesn't seem to have the option to input...