  1. sorin84

    Shaker load question

    I'm sorry! The unit for rms value is (m/s^2). Slip table + copling element + thermal barrier + moving elemet + fixture + screws + UUT's = 230kg
  2. sorin84

    Shaker load question

    The test has to be perform on the slip table. Total weight of all test setup - including moving element of the shaker is aprox. 230 kg.
  3. sorin84

    Shaker load question

    Each power module of the amplifier have a green (OK) and a red (not OK) LED. For the vibration test described above the green LED was ON permanent.
  4. sorin84

    Shaker load question

    Hello, I am new in vibration domain and I am looking for some information. I have to perform a random vibration test: Hz (m/s^2)^2 10 10 100 10 300 0,51 500 5 2000 5 R.M.S. acceleration 96,59(m/s^2)^2 Sigma clipping 3 Necessary...