  1. ellas1

    How can I calculate the temperature at the end of a Pipe Trunnion

    How can I calculate the temperature at a point of a Pipe Trunnion. The Pipe Trunnion is welded to a hot (steam) pipe. Thank you
  2. ellas1

    Cold & Hot Allowable Stress for A778 304L pipe

    What is the Cold & Hot Allowable Stress for A778 304L pipe. I cannot find this material on B31 tables. Thank you
  3. ellas1

    Unbraced Length

    I have an Unbraced WF beam Pinned at both ends and a post at mid-span which places segments of both the top & bottom flanges under compression. Is it accurate to use the location of the infections points as the unbraced length (where the moment switches from + to -) or the total length of the...
  4. ellas1

    Seismic Coefficient Rp for piping and its supports

    For ASME piping with joints made by welding or brazing Table 13.6.1 of ASCE 7-10 (Seismic Coefficient for Mechanical & Electrical Components) shows an Rp=12. However, section 13.4.1 of ASCE 7-10 Design Force in the Attachment) indicates that Rp shall not be larger than 6. Is the code expecting...
  5. ellas1

    Capacity of a CECO 12H3 Steel Joist

    thread507-270275 I need the load carrying capacity of an old CECO 12H3 steel joist at 17 ft O.C. If anyone with an old catalog can help it will be greatly appreciated. Thank you
  6. ellas1

    Nozzle Loads

    Problem: We have a vessel nozzle that is subjected to 3 thermal forces Fx, Fy, Fz and 3 thermal moments Mx, My, Mz with Fx the axial force and Mx the torsion. Even though all forces and 2 of the moments are much smaller than the given allowable's one of the bending moments exceed the allowable...
  7. ellas1

    Allowable stress for A53 Gr B pipe above 800 F.

    The ASME B31.1 allowable for A53 GR B at 800 degrees F is 10.8 and according to para 124.11. the upper temperature limit for this material is 800 except as permitted by para 122.6.2. Assuming it is permitted by 122.6.2, how can we determine the allowable at say 1100 degrees F? Thank you
  8. ellas1

    Roof jumping upwards with no apparent reason

    We have a large flat metal deck roof on 100 ft long steel joist @ 6 ft OC. The mechanical contractor has recently replaced 3 roof top units (Air Handling Units) with 3 new and lighter ones (approx 8 kip each). After the old units were removed and the new units installed several people working on...
  9. ellas1

    Pre-Manufactured Building Evaluation

    Any tips on how to evaluate the structural integrity of an existing pre-manufactured steel building with unknown MNFR.
  10. ellas1

    Wind loads on scaffolding

    I am searching for any information regarding what wind loads to apply when designing wall formwork, and scaffolding for the core of a tall concrete building. Any information will be appreciated
  11. ellas1

    Punching shear on a pipe cap

    Any tips on how to calculate the puncing shear on and end pipe cap will be appreciated. I have a 16" pipe welded to the end cap of a 24" pipe resisting a 15 kip force. Using STAAD FEA I get plate stresses that do not make sense and I like to check them manually.
  12. ellas1

    SS structural bolts equal to ASTM A325?

    Is there a SS bolts that is close or equal to ASTM A325 structural bolt? Some threads here call for A193 B8 but the yield strength of A193 is only 30. Any information would be greately appreciated.
  13. ellas1

    Split Sleve Couplings

    Any recommnedations on how close before and after Split Sleeve Couplings (Depend-O-Lock Couplings) we should provide supports will be appreciated. Thank you
  14. ellas1

    Element Size v Stresses

    I am very rusty with FEA. To check the effects of the mesh size with the accuracy of the results, I analyzed two 1/2"x4"x10" simply supported plates loaded with 10 psi on the local Z axis. The first plate was meshed with 1"x1" elements and the second with 1/4"x1/4". The stresses on the 1/4"x1/4"...