Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. harmsgundam

    ASTM C150 on Heat of Hydration Requirement

    Hi, I hope someone can enlighten me on what is the reason for ASTM to change the limit of heat of hydration value on Table 4 from 255kJ/kg @ 3days to 335kJ/kg @ 3days? This is a huge increase on the limit making the common type 1 cement compliant to type 2-MH as well. Will this change leads to...
  2. harmsgundam

    Flowable Fill as trench backfill on highway pavement

    We are planning to use a flowable fill as alternative backfill (subgrade level) on our utility trenched located on major roads. My major concerns are the following: 1. How long would it take (hours?days?) for the flowable fill to sufficiently harden before we can place a cement treated base on...
  3. harmsgundam

    SIZE OF BLOW OFF ASSEMBLY

    Is there any reference document that provides guideline on sizing of blow off assembly as per main water line diameter? Is there any reference computation? For example, can a 600mm dia. main line have the same size of blow assembly with a 2meter dia. main line?
  4. harmsgundam

    EPDM OR PU? WHICH IS BETTER?

    Hi All, I would like to ask the opinions of you guys on which is the better material to be used as sealant for the sluice gate in our wastewater treatment facilities. Is it EPDM (ethylene propylene diene monomer (M-class) rubber) or Polyurethane type? The thing is of course this will be exposed...
  5. harmsgundam

    Does Rain Hurt Compaction?

    Hi everyone. My question concerns the backfill on our pipe trenches. Our Contractors always say that the reason they are not utilizing the native material as backfill to our trenches is the problem with rain. They are saying that when their compacted backfill is exposed to rain (I expect...
  6. harmsgundam

    SAND AS TRENCH BACKFILL MATERIAL AND APPLICABLE COMPACTION METHOD TO BE USED

    Hi All, I am working as a Standards Manager in a water utility Company and currently we are having issues on the applicability of the backfill material we are using on our trenches and the right compaction method to be applied. I have attached a drawing of a typical trench section. As you can...
  7. harmsgundam

    Gravel Bedding for 900mm Diameter Steel Pipe

    Hi to all, I would like to ask if one can use gravel as bedding for a 900mm diameter steel pipe. If yes, what will be the size limit for the gravel to be used? Can you guys site any reference standards or documents to prove this usage? Thank you for those who can answer.
  8. harmsgundam

    DESIGN OF BEAMS IN BRIDGES

    Hi all, I am new in the design of bridges and I would like to ask for opinions regarding the design of longitudinal beams directly supporting the slab above. Is it fine to subject the longitudinal beam to the full load of an MS18 truck loading/ lane loading for example (i.e. 324kN gross...
  9. harmsgundam

    Design of connector spacers for Double Angle

    Hi all, We have a project regarding retrofitting of communication towers wherein I'll add an aditional angle bar to an existing diagonal member which is an angle bar as well of the same size. So the resulting section is a double angle. Now regarding the spacers to be place along the length of...

Part and Inventory Search