Gents,
Pump Service : Vaccum Bottoms Pump.
Pump Type : Axially split Double Volute Between Bearing pump with Horizontal cooling jacket.
Existing Piping Plan : 32/62 ( 32- with Seal with 220°C, 9 barg & 5-7 Ltrs/ min.)/ 62- with LP Steam Quench )
Seal Type : Stationary Metal bellows, Single...