  1. joedirt9

    Pressure loss through heat exchanger

    Not sure if i have enough data to tackle this one. I have a 1" pipe with water at 60 psig going into a heat exchanger. The heat exchanger discharges water at a flow rate of 20 gpm. I am unable to access the heat exchanger, but i know its there. How do i determine the pressure at the...
  2. joedirt9

    Max Amps?

    Looking to determine the remaining capacity of an Immersion Heater: 480 V 90 kW 1-3 Phase . The readings gave 67 Amps Any ideas on how to determine the remaining capacity of this heater?
  3. joedirt9

    ASTM Spec for A269 321 seamless Tube

    I am not able to find the allowable stress, ksi, at 572 F for this material. Any tips on what i am missing out on. Is this comparable to another material and i am just not aware of it? Thanks
  4. joedirt9

    BTU requirements for a Jacketed Pipe

    So there is an exhaust pipe that releases steam at 326C. This pipe needs to have a jacket placed on it to keep the steam at an elevated temp. so that particles to do not clog the pipe as they cool. This is an 8" pipe that is 10' long. I am trying to figure out how to set up an equation to...
  5. joedirt9

    Difference between 10WF21 and 10WF21-S?

    looking at some drawings and there are a bunch of old steel on here. There is 10WF21 and 10WF21-S listed and I was wondering what the difference was. Any ideas?
  6. joedirt9

    adding gussets to a pipe

    looking to add 4 gussets to a dip tube for extra support. not sure how to take into account the gussets when looking at the pie as a cantilever beam. the dip tube is 1 1/2" SCH40 and is 8' long. no way to support at the bottom of the pipe. fear is the pipe will break and be in the tank which...
  7. joedirt9

    Choked flow through restrictive venturi calculation

    Unable to find an equation that will let me calculate if the venturi is experiencing choked flow. I have inlet pressure, pressure drop and all the other useful info. but all of the formulas i have found require, FL^2, the recovery coefficient. Which I do not have any help?
  8. joedirt9

    Restrictive Venturi - Anyone have information about these?

    Need to design a restrictive venture, regular orifice wont work as there are solids. Does anyone have a way to calculate the dimensions? I am unable to find any equations THanks
  9. joedirt9

    What is this fitting

    I am trying to determine what this fitting is and where to obtain some new ones. It is currently being used to secure a SS hose hanging from above. The hose swings in and is clamped down with the two bolts on either side http://i578.photobucket.com/albums/ss227/joedirte9/photo.jpg