Hello Experts
for U-Stamp vessel design calculation i come across when UG 22(j)ASME Sec VIII-1 loading applicable means for hydro-static test loading, how to satisfy this condition.
Why normally designer check stresses during hydro should not exceed 90% of yield at test temp.
Anyone have experience working on integrally forged vessel as per Section VIII-1 ( Mandatory appendix 22) if yes can you please provide me some photos and technical paper about same?