Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: JoeBaseplate
  • Content: Threads
  • Order by date
  1. JoeBaseplate

    HSS Col-Beams from four sides

    I want to verify the changes I want to make to this attached obsolete detail. I have a HSS col with WF beams coming in from four sides. I can get a thru plate for connection from two sides but I am not sure about the other two sides. Could I use welded plates (as marked up) which are not thru...
  2. JoeBaseplate

    Concrete mix for exposed exterior slab on grade

    Party pavilion, open 4 sides, wood trusses on columns at roof. Location in IL (frost and snow). My question is about my slab on grade mix design. I have the following: Min f'c = 3000 psi. Min cement. Material = 520 lb/cubic yd. Max W/C = 0.40 Slump = 4" + - 1" Air content = 5.5% + - 1 This is...
  3. JoeBaseplate

    Concrete mix for exposed exterior slab on grade:

    Party pavilion, open 4 sides, wood trusses on columns at roof. Location in IL (frost and snow). My question is about my slab on grade mix design. I have the following: Min f’c = 3000 psi. Min cement. Material = 520 lb/cubic yd. Max W/C = 0.40 Slupm = 4” + - 1” Air content = 5.5% + - 1 This is...
  4. JoeBaseplate

    Column footing as a trench footing

    Has anyone ever done a column footing in form of a trench footing rather then a formed one? The question has come up on a project where due to time constraints the contractor wants to do trench footings at walls. That should be OK, I have done that before. But now they are wondering if they can...
  5. JoeBaseplate

    Green vs Black book

    Do the new building codes, like IBC 06/09 require the design per LRFD method? I haven’t done a lot of steel design in the last three years as I was doing concrete work full time so I am out of touch with the changes. Am I required to do a beam design per ASD and LRFD of the black book? I am...
  6. JoeBaseplate

    Net uplift on metal deck on bar joists

    What are the major effects of net uplift on a roof deck? I know that I have to show the net uplift on the documents for the joist mnfr to design for, which will end up in extra bridging lines. But what other major issues should I be concerned about? I believe that the 22 ga metal deck connection...
  7. JoeBaseplate

    Stoop detail question

    I need some insight on a stoop detail at a door entry. Please see the attached. My question: Is it a good idea to tie the sidewalk into the stoop? FYI- This is IL so frost heave is an issue.
  8. JoeBaseplate

    #82 S.J @ 20ö oc.-1950

    I am assuming that these are 8” bar joists. I’ll need to field verify but the site visit is a couple weeks away. Also the section shows a 2.5” plain concrete (no mention of rebar or mesh) over “steel forming” on top of these SJs with asphalt tiles on top. Did they actually used to use...
  9. JoeBaseplate

    Most common fÆm (masonry)

    I have seen number ranging from 1500-2500 psi depending on the engineer and the firm creating the drawings. I am used to 1800 psi but was recently suggested by a more seasoned engineer that this may be too conservative and I should use 2000 psi minimum as typically thats a minimum number the cmu...
  10. JoeBaseplate

    Roof metal deck allowable lateral deflection-Wind

    What are the limits for horizontal/lateral deflection of metal deck under wind loading? I am checking to see if a 1.5x22 Ga deck is OK for use. Using the vulcraft deflection formulas I am coming up with 1.5” deflection at the center. The roof line height is 31’ and the walls are precast. In the...
  11. JoeBaseplate

    Wood post-Wood truss connection

    I am working on a party pavilion with wood trusses, plywood roof, gyp ceiling and wood posts. Posts are 14’ oc and trusses are 2’ oc. The structure is open to the sides. I am having a very hard time getting the posts to work for unbalanced uplift wind load (fig 16-b of ASCE 7) and the posts...
  12. JoeBaseplate

    ASCE 7...Fig 16-B

    Trying to figure out wind loading on an open pavilion. The clear and obstructed wind flow is for ceiling and without ceiling (50% coverage), correct?
  13. JoeBaseplate

    Cantilevered column for wind load

    Please see the attached sketch. This is a proposed frame for a single story structure, the exterior walls are masonry and there are no interior walls for use as shear walls, thus the need for frames. Wind is the governing lateral load (seismic site class B, Chicagoland). I was going to use...
  14. JoeBaseplate

    Basketball court SOG thickness

    SOG for a BB court in a community center (supposed to be HighSchool grade BB court)with proper flooring: I have used 4" thick SOGs for autoshops without problems so I think a 5" thick slab should work fine. Any input from folks here would be great.
  15. JoeBaseplate

    Plywood Cantilever

    Can roof plywood sheething be cantilevered? I have a shelter for a golf course where the arch wants to have the 3/4" plywood stick out at the edges by 24". Roof support behind the cantilever is prefab trusses @ 24" oc. I recall to have read somewhere that you can't cantilever any grade of wood...
  16. JoeBaseplate

    8x8 post fixed base

    I can't recall to have ever fixed the base of wood post. I have a situation where I might have to do that. I couldn't find an appropriate simpson base anchor for that. Is a custom built base plate the way to go? I am thinking of a steel base plate with welded HSS to fit the 8x8 in.
  17. JoeBaseplate

    Grade Beam @ Column

    Situation: New addition next to existing construction. There are no documents for the existing building so we have no idea what the existing footing capacity is like. Therefore I am reluctant to place any new loads on the existing. I am proposing the attached detail, basically using a cantilever...
  18. JoeBaseplate

    Ponding on flat gym roof

    I have a 68x100 gym with flat roof (metal deck on LH joists). Support walls are precast with 2’ parapet (may change). Ground snow load in the area is 25 psf. Per ASCE-7, as I understand it, I am going to check the lowest point on the roof for ponding with primary drainage system blocked. But...
  19. JoeBaseplate

    Rock @ 3'

    I know this is a very stupid question but I am being bugged constantly by the architect to get an idea for estimate purposes of what the footing sizes would be for a 7 story structure. He keeps telling me to assume rock at 3' depth (river bed in the area). I know what to assume for regular...
  20. JoeBaseplate

    Parking Garage LL

    Just wanted to confirm that LL for a parking garage is 40 psf (ASCE-7). Seems kinda low, so wanted to double check. Also, in a multistory parking structure, would you impose full or partial snow load over this 40 psf at the roof level?

Part and Inventory Search