Dear Sirs,
There is a restriction in the ASME B31.1, Allowable stress Table A-10 for the use of ASTM A193 B8 Cl 2 bolting material above 100 deg F. The allowable stress values were given up to 100 Deg F only. We understand that the B8 Cl 2 material can not be used more than 100 Deg F.
How ever...
When we are working in a Oil & Gas or Petrochem projects, the process persons specifying the Non Slam check valve in the P&ID's. In general, Non slam check valve means we will consider the Nozzle type. How ever some vendors proposes the Dual plate check valve as Non Slam Check valve. Of course...