  1. delf

    steam and condensate balance calculation and software

    Dear Sir I am encountering a project that is required us to do the steam and condensate balance caluation under normal condtion / feed variation condtion / start-up condtion / shut-down condtion. Could you please share any book or related software information allow me to do this calculation...
  2. delf

    thermosyphone reboiler inlet/outlet pressure drop sizing and velocity

    Dear Professional eng-tips member I have a project required to size the inlet/outlet pipe size of thermosyphone reboiler. And, our deisgn guide is written that the liquid vleocty to the reboiler in the range of 2 to 7 ft/s. And, the pressure drop in the line to the reboiler is requried to be...
  3. delf

    heat excahger tube length & inlet flow rate scale up

    Dear eng-tips forum members: My new project plant capacity is scale up from 3000 tons to 6000 tons. And, new project shell and tube heat exchanger duty is scale up from 1000kw to 2000 kw. I wonder I only knew the heat excahger data sheet infromation from 3000 tons plant. How could I develope...
  4. delf

    Desuperheater's Flow meter relation with P/T compensation

    Dear Sir As we know, steam flow measurements, being compressible, always require both pressure and temperature compensation. But, I am confused why a steam flow meter/indincator are installed. (Please see the desuperheater with 3 control loop drawing in the attached post) Is this steam flow...
  5. delf

    Low Level interlock trigger pump pushbutton to shutdown the motor

    Dear Sir I wonder how to show the right way that the software signal from interlock to shutdwon the motor. Please see the attached drawing. case 1 : As liquid level's low low, the singal will interlock through the pushbutton to stop the motor, and the pushbutton only be activated as interlock...
  6. delf

    Is pressure control valve good enough than solenoid

    Dear Sir Sorry to bother you this simple solenoid question. There are two case of pressure control valve. I wonder why we always pick pressure control valve (case 1) instead of pressure control valve with solenoid (case 2). In my poor undestanding about...
  7. delf

    Control / alarm set point for desuperheater

    Dear Sir I am sorry to bother you this simple control / alarm set point question. Case 2 is a simple direct temperature control through a temperature sensor located downstream and send a siganl to the valve controller to increase or decrease the water supply. Case 1 is a complex temperatrue...
  8. delf

    Acetic acid inelt flow low alarm necessary

    I am sorry to bother this silly and trivial. Does it is necessary that process engineer provdie low flow alarm/setpoint for this mass flow meter considering the following process, "the acetic acid flow into the reactor"? Also, a client requires the readout on the DCS, process engineer...
  9. delf

    Overflow tank control question

    Dear fourm members: I have an overflow tank. There is a overflow pipe connected on top of the tank, and through gravity flow to a seal pot. The service water will flow through a solenoid valve(XV-A) with level control(LIT-B) to the seal pot. It is confused me that the interlock in this...
  10. delf

    spectacle blind close/open selection

    Dear professional I notice that almost line drain in P&ID (operating / non-operation drain) always has isolation valves or isolation valve before spectacle blinds (usually closed) at these drain line from equipmennts or process main lines. Howver, in hazardous service, such as hydrogen...