  1. Nivrah

    Root cause analysis of ball bearings

    Hi all, I have an NSK deep groove ball bearing designation num 6008.This has 12 ball elements. Can anyone point out another bearing manufacturer equivalent that has the same number of balls? or more! Secondly: We have had numerous failure of this 6008 NSK and I suspect that it may be mounting...
  2. Nivrah

    cooling tower selection

    Hi guys, I am in the process of obtaining quotes for cooling towers. Do you guys know what info I must give the supplier to size and select according to my needs? So far I have: Design heat load design wet bulb temperature range Approach make-up water desired cycles of operation. are there...
  3. Nivrah

    chemical dosing schemes

    Hi all, I have been asked to undertake the preliminary design of a closed circuit cooling for our turbine room (turbines and compressors) cooling water. System flow is about 12 ML/day. Could any of those experienced with closed circuit cooling thrown some ideas about how I go about establishing...
  4. Nivrah

    Chemical dosing schemes

    Hi all, I have been asked to undertake the preliminary design of a closed circuit cooling for our turbine room (turbines and compressors) cooling water. System flow is about 12 ML/day. Could any of those experienced with closed circuit cooling thrown some ideas about how I go about establishing...
  5. Nivrah

    Factors affecting Overall heat transfer coeff

    To those experienced with HX's, An external body did a heat and mass balance in our plant where they used a HX with the following specs for a given set on inlet conditions: Area: 180 sq metres. LMTD: 4.6 U: 3436 W/m2.⁰C Duty: 2823 kW. Assume there is no fouling, My question is: Is U a constant...
  6. Nivrah

    pump curve

    hello all, just wondering if anyone has the following pump curve: PUmp: worthington Model:6LR-13A Rpm: 1475 kW: 30 thanks,
  7. Nivrah

    heat exchanger thermal analysis

    Hi all, I am investigating the analysis of an existing heat exchanger subjected to changed inlet conditions.Somehow its confusing me. So hopefully your input will help. here is the current config: water/water shell and tube HX hot water in = 90 degrees C hot water out = 40 degrees C hot water...
  8. Nivrah

    Pressure at discharge elbow exit of PSV

    Hi all, I have got a question pertaining to the equation used in ASME B31.1 Non-mandatory Appendix 2 where it calculates the pressure at discharge elbow exit (P1). 1.Does anyone know where this formula comes from? 2.The ASME code also tells that an alternative method should be used for...
  9. Nivrah

    Boiler Drum safety valve

    Hello fellow engineers, I am sizing 2 boiler drum safety valves set at 7412 kPag(drum design pressure) and 7620 kPa (1.028% of 7412 kpag). The required discharge capacities and minimum discharge area of the valves have been calculated and checked. However, I have also been told to calculate the...
  10. Nivrah

    Bolt Thread compatibility

    Hi All, Does anyone know if a BSW (british standard whitworth) bolt can mate with an UNC nut or vice versa? I looked up charts and found that the threads per inch (TPI) for BSW bolts and UNC bolts are the same for all sizes except for 1/2" size.
  11. Nivrah

    Automated grease dispensers

    I would like an advice on automatic grease dispensers. It is good maintenance practice to relubricate bearings at regular intervals (months) and whilst some require very small amounts, other bearings may require over 100 grams for eg. Two methods are currently widely used: the manual grease gun...