Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: RDW100
  • Content: Threads
  • Order by date
  1. RDW100

    ABAQUS display beam element member end releases

    Hi, I am wondering if anyone could tell me how to display member end releases in ABAQUS? I have changed some beam elements from fixed to pin ended and would like to visually see that this has been done correctly. I have made do so far by looking at the deflected shape but as they are connected...
  2. RDW100

    Fatigue assessment of vehicle impact girders

    I am doing a structural assessment of a steel concrete-composite bridge that has been impacted by an over-sized load. The impact has resulted in some significant plastic deformations of the steel beams. FE analysis has shown that this does not greatly affect the moment capacity of the bridge...
  3. RDW100

    Impact damage to steel bridge beams

    I am analysing a steel-concrete composite bridge that has been impacted by an oversized load, causing large plastic deformation of the lower flange and web. Could anyone advise whether this plastic deformation will have altered the material properties of the high yield steel beams? With...
  4. RDW100

    Print results to output window

    Can anyone tell me how to print element table results to the output window?
  5. RDW100

    Marine grade steel fire design

    I am investigating if there is a difference in fire design to BS5950-08 between standard structural steel (BSEN 10025) and marine grade steel (BSEN 10225). Is there a difference between these different types of steel and, if so, where could I find details? Is it "wrong" to use BS5950-08 using...
  6. RDW100

    BS 10225 Marine grade steel Fire design

    I am investigating if there is a difference in fire design to BS5950-08 between standard structural steel (BSEN 10025) and marine grade steel (BSEN 10225). Is there a difference between these different types of steel and, if so, where could I find details?
  7. RDW100

    Nodal solution contour plot text

    I want to have a contour plot showing nodal displacement as well as the node numbers. However the countour plot displays text saying "max" and "min" on top of two node numbers and makes them unreadable. Is there a way of turning the max and min text off so I can have the contours as well as...

Part and Inventory Search