  • Users: TANKO
  • Content: Threads
  • Order by date
  1. TANKO

    Corrosion Allowed for an Old EFR

    Good Morning to all, i have a question. In a terminal where i'm working, we would to do the thickness control of the External FLoating Roof of an hold tank. We don't have drawings about that tank. Does API provide acceptability percentages for the thickness test? Thank you very much in advance...
  2. TANKO

    Cathodic Protection

    Does the cathodic protection make sense for a concrete slab foundation? For me, no. What do you think? Thanks Regards
  3. TANKO

    Toe Cold cracking of welds

    Good afternoon to all, i have a question for you. During maintanace operations of a tank, it's necessary to open a temporary door in the 1° shell course. After 2 months that door was welded and regularly checked with RT and MT with with no defect, some toe cold cracking appeared in the...
  4. TANKO

    WRONG ROOF NOZZLE OPENING

    Good evening sir, if the construction company fails in the opening of a nozzle in a roof so they must close the hole, what's the procedure to follow? Re-Welding, 100 % RX.....ETC ETC What does API recommend in a similar situation? regards
  5. TANKO

    Tank Dent Aceptance Criteria

    Good Evening sirs, what are the acceptance criteria for a tank vent? During the construction, perhaps for a incorrect procedure welding of a stair support, we have suffered this distorsion. thanks regards
  6. TANKO

    Maximum filling rate hydrostatic test

    Hi guys..help me To understand chapter 7.3.6.5.API 650 First of all i think that this is a duty of The purchaser. Please confirm me. Then, is 460mm/h The filling rate???Can You explain me The meaning of this value? I think It' s To much low But i m sure i m Not understanding. Thanks
  7. TANKO

    Tank Foundation Question

    Good Evening everyone i have a technical question about the foundation. Where i'm working the client is using a kind of bitumen emulsion on the sand as final layer. In the civil drawing i read "50 asphaltic sand" as final layer. From my point of view the procedure of the client is not correct...
  8. TANKO

    Welding sequence for shell-annular

    Good Evening to all i'd like to have a clarification. Does API650 provide that for the welding annular-shell you have to start from the inside of the tank and not from the external? thank you regards
  9. TANKO

    SHELL COURSE HEIGHT FOR TANKS

    Good Afternoon srs does API 650 provide for the shell course a minimun height or maximum for the shell courses?? for example can we design a tank of 8m in height with 4 courses of 2m of height or with 3 courses of 2.6 m?Obviously the calculation must be verified...Ok then we can talk of good...
  10. TANKO

    Stainless Steel Welding FCAW

    Dear all, i'm writing to have some technical advice about a situation that we have in our site. We are building some pipelines for liquid gas but we have a problem with some joints infact it's impossible to weld with the purging because we don't have any solutions to pull out the plugs. The...
  11. TANKO

    URGENT LOOKING FOR A INOX PLATES WITH HOLES FOR FILTERS

    Good evening, i'm a Project Manager of a bunker terminal in construction in Panama. I'm looking for holes plates in stainless steel. Here the specifications: Material: Aisi 304 Thickness: 8 mm Holes diameter:6 mm Distance holes-holes: 8/9 mm I need about 3 plates of 48"x96"...but it is not...
  12. TANKO

    Problem with installation Primavera P6.2.1

    Good evening to all. I have some problem with the installation of primavera P6. This is the message of error " Bad public user name or password. Database Server Error: SQL Network Interfaces: Error Locating Server/Instance Specified [xFFFFFFFF]." I have installed P6 as stand alone but when i...
  13. TANKO

    Info double annular plates API 620 - LNG Tank

    Good afternoon, In the drawings of our client,we are realizing that there are 2 rings of annular plates (for the bottom vapour barrier). Where can i see this construction detail in the API 620?I would like to know the technical reason. We are building a LNG tank. Regards
  14. TANKO

    Information about inches calculation

    Good evening, a stupid question for you...but very important for us. So, we should calculated the inches of welding from 500 sketches dwg. We are not specialized in piping. We are proceeding in this way: for example 10 joints from 10" = 100" It is correct?We are not calculating the development...
  15. TANKO

    Monthly Progress Report for Piping Works

    Good afternoon to all. So, i don 't know if this is the correct section for my question. Anyway, i'd like to know the best way to make a report for monthly piping progress to issue statement. We have material supply (pipe, elbow,valves,...), pfa and erection. Moreover, for each item we have the...
  16. TANKO

    SOAP SUD TEST ON ROOF NOZZLE & MANHOLES?

    Hi to all....a question for you... Which chapter (API 650) talks about soap sud test on roof nozzle and manholes? thank you in advance
  17. TANKO

    Tank Foundation Responsability

    Hi...another question...Who is the responsible for the acceptance of tank foundation??The site manager or the quality department?Does Api code give some indication? (According to the mechanical company..) Thanks for the answer
  18. TANKO

    Foundation Control

    Hi 1000$ for the correct answer:) I d like to understand better the chapter 7.5.5.2 & 7.5.5.3 about foundations control before erection. For 7.5.5.2 should we check only the contour?????It seems clear. For 7.5.5.3 it talks about "specified high point" What does it mean?Is it an external point to...