Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: gelsi
  • Content: Threads
  • Order by date
  1. gelsi

    waste water storage

    Hi, do you have any guidelines, rules, practices, standards about this topic: - storage in steel tank of waste water, with hydrocarbons into solubility range, discharged by a chemical plant: distances from plants, if or when needed a basin and waterproof floorring, etc. tx
  2. gelsi

    storage dirty water or waste water, with hydrocarbons into solubility range

    Someone can help to find guidelines, rules, practices, standards about this topic: storage of dirty water or waste water, with hydrocarbons into solubility range, of a chemical plant: distances from plants, if or when needed a basin and waterproof florring, etc. tx
  3. gelsi

    flow in an horizontal circular open channel

    hi, in an horizontal circular channel there is a flow of liquid, it's not full of liquid. Here is the question: 1 - is there a reduction of level along the pipe? 2 - if yes, how can be estimated?
  4. gelsi

    refractory failure

    Hi, i don't know if this is the better forum for this question: there is a method to define how much air needs to cool an hotspot (refractory failure? tx
  5. gelsi

    thread330-302874 hi ref. "The p

    thread330-302874 hi ref. "The practise here is we apply cooling steam hose at the hot spots/stingers & it is kept until next outage of the equipment where the necessary actions are taken to repair the refractory." where can i find the design criteria to define flow rate of external cooling...
  6. gelsi

    behavior of a PSV for gas when the system protected needs a continuous very low discharge flowrate

    Hi, an auto regulation device of upstream pressure loses its seal while the downstream pipeline is blocked in; so the pressure rises to the set value and the PSV start opening. The leakage flow is a very low fraction of nominal flowrate od PSV, for example 1% or minus. What scenarious you think...
  7. gelsi

    EHN RUNAWAY AND SAFETY RELIEF

    Hi, any experiances with 2-ETHYLHEXIL NITRATE and its thermal runaway? How calculate safety device for?
  8. gelsi

    flow throught inertization

    Hi, this is the question: i have a "flow through inertization" of an external envelope with the scope of reducing internal corrosion due to air, so i have to maintain a low content of humid air inside the metal envelope. Do you know a criteria for flowrate? I think it could be very low, > 0.2...
  9. gelsi

    one SV protects 3 or more equipment

    Hi, an other question. Normally, several plants have one relief valve that protects more than one equipment. I think it's a good design criteria to minimize the number of valves but if there is the fire contingency, maybe it's better to install more valves: when the equipment group is located...
  10. gelsi

    Very high pressure gas relief - supercritical - Z>2

    Hi, could you help me with the approch to a PSV calculation? Follow some conditions: fluid ethylene critical pressure 50.6 bar relief pressure = 3000 bar relief T = 80°C density about 602 kg/m3 Z by density ~5 It has the density of a liquid but is a supercritical gas, which calculation method...
  11. gelsi

    very high set pressure ~43500psi

    Hi, I'm looking for manufacturers of PSV with set 43500 psi, can you help me? Tx
  12. gelsi

    Vapour recovery ship loading

    Hi, how can be solved the case of sour crude ship loading? Active carbons have problems with sour gas... has anyone experiance? Thanks
  13. gelsi

    ref. max speed of external floating roof

    Hi, who can comment this post? tx Link
  14. gelsi

    max speed of external floating roof

    There are any limits to the speed of an external floating roof (API650 hydrocarbons) during operations? Somewhere I read ~3.5 m/h, that's correct? There are useful technical references? The objective is to carry out safe loading/unloading operations. Thanks
  15. gelsi

    existing hand-valves CV

    Hi, when need modifications of existing systems, we must often estimate the CV of hand-valves (example 1/2" gate valve on nitrogen blancketing line). Anyone can help me, i tried to find a table... Tx
  16. gelsi

    fractionation vacuum tower overhead

    Hi, i am looking for overhead-line's design criteria, the goes from vacuum tower (0.45 bara) to condenser. tx
  17. gelsi

    demister pressure drop calculation

    Hi, anyone can help me to find methods for wetted and dry PD? i have only these data: tipe CWMS density 160 kg/m3 thick mesh 150 mm free vapour flow area 0,385 m2 flowrate 2000 Act m3/h
  18. gelsi

    steam tracing

    Hi, I have a line of incondensables+condensables at 40°C that is bare, without insulation and with pockets. The fluid reduces its temperature because it exchanges heat with the ambient (convenction, wind action, radiation, etc) and condenses, so it needs to design a system to avoid liquid...
  19. gelsi

    Hi this is my question: what's th

    Hi this is my question: what's the meaning of "The CET for systems constructed to ASME B31.3 is defined as the lowest metal temperature at which a component will be subject to either 30 percent of the maximum allowable working pressure (MAWP) at ambient temperature or a combined total...
  20. gelsi

    thermal relief flowrate of steam traced pipe blocked in

    Hi I'm going to define an overpressure protection device for a steam traced & insulated pipe-line. How can calculate or estimate the heat-trasfer coefficient U or the max thermal flux to the fluid? There is a short-cut method? Tx very much Main data: fluid heavy oil normal temperature of fluid...

Part and Inventory Search