  1. prichmon

    Time and cfm for cooling aluminum rods

    Good afternoon; Could someone assist me in verifying my calculation? Or point me in the right direction to a reasonable estimation? I am attempting to work out a decent mathematical model for cooling round solid rods on a cooling bed. The material needs cooled from a high of 700*F to 150*F...
  2. prichmon

    Looking for tubing or bar stock in 5.5"

    Anyone have a line on who make 5.5" bar stock or tube with no more than a 3.5" bore? Thanks Rich
  3. prichmon

    In what instances can Bushings be Used in Fuel Gas Piping

    Could someone please verify my research on the use of bushings in fuel gas pipe? My understanding from searching on Google is only malleable iron when reducing more than 1 size is acceptable. No Cast Iron. 1209.5.8.4 Metallic Fittings (Including Valves, Strainers, Filters). [NFPA 54: 5.6.8.4]...
  4. prichmon

    Geothermal piping calculations

    We are looking at replacing a Cooling tower with Geothermal Cooling for a process water loop. 80KW total power usage. 10*F temp differential on cooling tower design 20*F temp design differential on system operating pressure 30psi If we move to geothermal cooling our temp differential will be...
  5. prichmon

    Natural gas line sizing

    We are going to a new gas main system. The existing system is 3" black pipe at 15" WG. I am looking at changing pressure from the existing 15" WG to 7" WG, 2psi or higher. I would like your opinions for 2 reasons; 1 I am studying for my PE and wish to know the "test" method for calculating this...
  6. prichmon

    sizing a simple stack for heat draft off a furnace

    I am working on installing a simple hood with stack to draft the heat from a 1,000,000 BTU/HR furnace with a vertical escape and horizontal run. The unit uses a blower running ~7" WC. Furnace opening is ~3"x 36". My current plan is to use a simple rectangular sloped up hood attached to stove...
  7. prichmon

    induction brazing heaters

    I am a little out of my realm. We are working on a late 70's induction brazing unit 40KW which has been blowing fuses. I have dealt with the primarily mechanical side and wish to move to the theory of operations. I have read through what literature I can find but am still left with questions...
  8. prichmon

    October PE Exam in WV

    I have been selected to take the PE next month and have selected the mechanical systems and materials for the afternoon. I waited 7 years before taking the FE and do not recall anything about the discussion of PE prep or suggested materials for the test during my college days. I understand the...