20" long radius elbow (thk.6.35mm) getting displacement of axial direction 46mm on operating case (Design Temperature). after putting loop on line
This 46mm is acceptable or not?
Thanks regards
dear all
Vertical can Type Pump (Can Dia.355mm & 2521mm Length)at very high seismic zone & Earthquake.
To protect this vertical pump from High Seismic zone & Earthquake.
we are planning to do below method's
(1) Appropriate support position by FEM analysic
(or)
(2) Metallic...
LPG piping design temperature -45 deg c to 50 deg c and design pressure 40kg/cm2 g
And material for this line is A333-6 SEAMLESS
Valve vendor want to supply
Ball Valve Body material ASTM A351 Gr.CF8M can use instead of A 352 Gr.LCB
Ball Valve Body material ASTM A182 Gr.F316 can use instead of...
VERTICAL LPG PUMP IS DESIGNED ACCORDING TO API 610 10TH EDITION
AS PER PUMP VENDOR DRAWING,
PUMP SUCTION NOZZLE SIZE 6", PUMP DISCHARGE NOZZLE SIZE 4"
AS PER P&ID
PUMP SUCTION LINE SIZE 6", PUMP DISCHARGE LINE SIZE 6"
IS POSSIBLE PIPING WORK CAN BE DONE WITHOUT REDUCER AT SUCTION NOZZLE ...