  1. msboobathi

    Distance between splices

    Dear All Are there any specifications for the distance between splice. The contractor erected the column 100 mm outside with a stub. He also brought the beam with its original length. Now asking for a splice of 100 mm length. Beam is HSS 500x400x tk. Usually, we will allow the splice Depth or...
  2. msboobathi

    Wind load : Triangular shape building

    Dear All How to compute wind load for triangular-shaped building. please provide some reference Regards M.S.Boobathi
  3. msboobathi

    Connection Design Forces

    Dear All I request to share valuable experience about "How to provide Connection design forces on Drawing ". This takes long time OR is it acceptable practice the structural model Regards M.S.Boobathi
  4. msboobathi

    Weld between Web and flange shear flow Built up box

    Dear All I am designing the weld for Built up box RHS 300x120x16x12 ( subjected to Axial force +small flexure) The shear capacity = 2*0.6*0.9*fy*t*D = 2*0.6*0.9*355*12*300 = 1380 kN Equivalent horizontal shear =Vmax*1000 *AF/I = 1380*1000N*[120X16]*150/116009344 = 3426 kN Required fillet weld...
  5. msboobathi

    STEEL REINFORCED COUPLING BEAM SRC - SHEAR STUDS

    Dear All There are procedures to calculate the shear studs in plate reinforced coupling beams I couldn't see such requirements in Steel reinforced coupling beam. Are they not required. Can i get reference (AISC /ACI) for designing steel reinforced coupling beams Regards M.S.Boobathi
  6. msboobathi

    Maximum weld thickness

    Dear All I am checking a HSS punch plate welded connection for the revised forces . i need more weld is acceptable to provide 18 mm weld with punch plate where as the wall thickness is only 16 mm...
  7. msboobathi

    Wind load for inverted curve building

    Dear All We are designing a different building skylight !! with inverted curve in both direction as attached . how to calculate the wind speed ? Regards M.S.Boobathi https://files.engineering.com/getfile.aspx?folder=a24dd4c0-df35-46ce-b3f0-0d88d57182b1&file=WIND_LOAD_QUERY.png
  8. msboobathi

    Idea statica modeling of embedment connection

    Dear All Any one modeled simple beam to core wall connection Regards M.S.Boobathu
  9. msboobathi

    Grouping Member forces for connection design

    Dear All I would like all to share their experience how to share Group the forces when there are lot of steel members and combinations . How to present in drawing format ? Is there any simple consistent approach Regards M.S.Boobathi
  10. msboobathi

    Openings in coupling beam PRC

    Dear All 1) Is there any reference to design PRC Coupling beam with openings Regards M.S.Boobathi https://files.engineering.com/getfile.aspx?folder=4a887d45-d04f-4a2a-9115-0076e4a7e4e3&file=Opening_in_coupling_beam.PNG
  11. msboobathi

    Design of pin connection+base plate

    Dear All I am designing Pin connection as in attached figure. please share as reference (AISC-LRFD ) connection design example/ Spread sheet for pin connection+base plate Regards...
  12. msboobathi

    Wind load for curved sign board

    Dear Engineers Please suggest me method or reference to calculate wind load for curved sign board attached to building as in attachment Regards M.S.Bhttps://files.engineering.com/getfile.aspx?folder=71e52609-1eb4-40ba-bac6-8465ae9a50be&file=Sign_board_Wind_load.png
  13. msboobathi

    Mezzanine beams connection to Concrete columns

    Dear all I am designing a post fixing connection for Mezzanine steel beam to existing concrete columns the post fixing connection fails ? Can any one share a better idea ? column size 500mmx500mmX6mheight Factored shear force on x direction beams = 100 kN Factored shear force on x...
  14. msboobathi

    Design of Elevator dividing beam

    I have been asked to design elevator dividing beam to support guide rails & brackets. There are guide rails attached to a frame is attached to dividing beam . Please refer the attachment if the supporting brackets are attached to dividing beam , the tip of U shaped frame is deflecting more...
  15. msboobathi

    Seismic Analysis

    I am desiginging a steel building above concrete building . While analysing i m getting more drift due t seismic loads. What is the appropriate way to model this. Regards M.S.Bhttps://files.engineering.com/getfile.aspx?folder=1db65894-8bde-4440-ba0a-0b6380e7a409&file=ABC.png
  16. msboobathi

    ACI 349-01 MULITIPLE SHEAR KEY / lugs

    DEAR EXPERTS I am designing multiple shear lugs to resists 2700 kN. is my unnderstanding is correct as per the attachment for concrete breakout . any other checks to be prefromed for breakout. if i have an example solution it will be much helpful. if this check is not satisiyed...
  17. msboobathi

    Lift guide rail supporting brackets Impact factor

    I am designing Lift divider beam to support guide rail through brackets. The lift contractor provided the loads (Horizontal loads are predominant . Please refer the attachment ) . What should be the Impact factor for the Loads preferably with code reference Thanks in advance Regards...
  18. msboobathi

    bolt bearing

    As per AISC-360 bearing strength of bolt holes is given as i) When deformation at the bolt hole at service load is a design consideration Rn = 1.2lctFu ≤ 2.4dtFu . What is the meaning of "service load is a design consideration " and when to use Rn = 1.5lctFu ≤ 3.0dtFu Thanks and regards...
  19. msboobathi

    Goliath Foundation

    Dear All I need to design foundation for 40 T Goliath. I dont have standard references . Please share the details if u have. Is there any Expansion joints to be provided (175 m long) Thanks and regards M.S.Boobathi
  20. msboobathi

    ASCE Wind loads on roof

    Figure 27.4.8 Wind load cases is applicable for Walls.. For the same cases How to apply Wind loads on roof ? I here with attached sketch . Is that correct ? http://files.engineering.com/getfile.aspx?folder=374d7f2a-e86a-4aa3-8289-9ff9ba33c740&file=MX-M753N_20150119_220228.pdf