The formula for tau in Diagram 8.3 of the 3rd and 4th editions should be (2.4-l.bar)*10^(-phi(l.bar)). The values in the table are ok.
Fudd's First Law of Opposition: "If you push something hard enough, it will fall over."
Teslacle's Deviant to Fudd's Law: "It comes in, it must go out."
A tank is designed to ASME Section III. No relief valve was provided on the tank, because the tank was designed to system design pressure. FME evaluation postulated failure of the pump control system leading to overpressurization of tank.
Does Section III allow taking credit for the B31.1...