Hi,
Is there any reason why we should not use 2 seperate panels instead of one large on for this CDT test.
Usually one panel will be immersed with holiday and the other half above the water source (vapour zone).
We have been supplied with 2 panels (not big enough to immerse and have a...
Has anyone ever done this test? If so, please could you forward a photograph of your set-up? Thank you.
"The purpose of this test is to determine if the sleeve has adequate resistance to shear stresses that might result from friction between the coating and the ground during pipe movement. The...
Hello,
I am a coating's technologist currently handling a huge throughput of cathodic disbondment testing (CDT).
We are a UKAS approved laboratory for this test, i.e. we must maintain everything according to specification for the duration of the test.
I am seeking suggestions for the most apt...