Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: aatara
  • Content: Threads
  • Order by date
  1. aatara

    Cv vs Position in a Gate Valve

    Hello to everybody Do you know a Table or Figure where could I calculate the Cv of a standard gate valve vs open or degrees of opening? My valve is a 10" 150 -lb wedge-shaped Carbon Steel and I don´t have documentation of the valve (20 years old) Regards,
  2. aatara

    Improve an Air Cooler with spraying water

    Hello to everybody. I am studying the viability of spray water before an induced air cooler to reduce DBT air entering. My doubts are next ones: 1. Do you know experiences positives with this solution? 2. How could I estimate the real reduction of the DBT spraying a quantity of fine drops...
  3. aatara

    Centifugal pump with water and air

    Hello to everyone I have a closed cooling system with a horizontal pump (KSB 14000 gpm - 200 ft) and several heat exchangers. The normal operations condition are 120 psig and 100 ºF. I´d like study special situation where a failure in a pipe could allow air enters into the circuit. How does...
  4. aatara

    SS 316L with Carbon steel A106 GrB

    Hello, Could anyone explain me the corrosion problem in an array of pipes made of A106 GrB, where I connect terminal fitting (spray nozzle) and pipes of SS 316L? How could I protect the terminal pieces of SS from corrosion (galvanic piles, pitting, etc)? Thanks in advance
  5. aatara

    Inside diameter under tolerances

    Hello, Anyone could help me to find in what part of the code ASME explains the rules or requirements to increase the inside diameter of a 90º bend? I have several 90º bends 30" SA234WPCW Sch XS. After a dimensional test, the inside diameter in some parts of the ends is below of the ANSI...
  6. aatara

    Inside diameter below of tolerance

    Hello, Anyone could help me to find in what part of the code ASME explains the rules or requirements to increase the inside diameter of a 90º bend? I have several 90º bends 30" SA234WPCW Sch XS. After a dimensional test, the inside diameter in some parts of the ends is below of the ANSI...
  7. aatara

    DVD external player for mobile PC

    Hello to everyone: I have a PIII mobile PC with a CD/RW, but I need play movies un DVD. How can get that in a not very expensive way?. I only know one DVD external player of FREECON (port USB), but it´s very expensive for me (more than 160 $) Thanks.
  8. aatara

    Special valve for cavitation[/]

    Hello, I hace two multiorifice in serie that produce cavitation in a water coolant system of a nuclear plant. The DP is aproximately 3 kg/cm2 (Outlet pressure is atmosferic). Do you know special valve to change my passive design and that reduce or eliminate the cavitation?. This valve must be...
  9. aatara

    Cavitation after a RO

    Hello, I have a 316 SS 30" (Schedule XS) pipe after a multiorifice plate in a water cooling systems of a power plant. I have signs of cavitations (sounds). I´d like know the problems associated and the erosion-corrosion rate. Should I test the pipe unde UT to determine the evolution of...
  10. aatara

    Corrosion in 316 under cavitation

    Hello, I have a 316 SS 30" (Schedule XS) pipe after a multiorifice plate in a water cooling systems of a power plant. I have signs of cavitations (sounds). I´d like know the problems associated and the erosion-corrosion rate. Should I test the pipe unde UT to determine the evolution of...