  1. Oversee

    Pattern loading for 2-way slab (ACI 318-8 method)

    ACI 318-8, clause 13.7.6 gives requirement for arrangement of live load on 2-way slab: 1) Pattern loading is not necessary if unfactored live load is less than ¾ of the unfactored dead load. 2) 75% of the full factored live load on appropriate panels is required if pattern loading has to be...
  2. Oversee

    ASCE 7-05 12.4.2.2 vertical seismic load effect on foundation design

    Ev=0 is required for those load combinations containing Eh-Ev when checking “soil-structure interface of foundations”. I am not sure about this terminology at all. Does soil-structure interface demand cover all checks such as ground bearing, overturning and sliding? My second question is: why...
  3. Oversee

    Clause 2.1.2.3 ACI530-05: allowable stresses increase 1/3 for masonry

    Clause 2.1.2.3 ACI530-05: allowable stresses increase by 1/3 for masonry Three load combination C) D) and E) are allowed for this strength increase, besides those “permitted by the legally adopted building code”: 1. D+L+(W or E) 2. D+W 3. 0.9D+E My load combination has an extra ingredient...
  4. Oversee

    ACI 318-8 requirement for 2 way slab openings

    “ACI 318: 13.4.2.1 – Openings of any size shall be permitted in the area common to intersecting middle strips, provided total amount of reinforcement required for the panel without the opening is maintained.” I totally agree with the first part of the sentence. My interpretation about the...
  5. Oversee

    Is it necessary to do strength design for concrete footings assigned t

    Apart from the settlement and overturning requirements (12.13.3 and 12.13.4 of ASCE7-5) for footings as parts of structures assigned to seismic design category B, are their other requirements for concrete isolated or combined footings in terms of strength and detailing? Thanks
  6. Oversee

    masonry infill panels designed not to take any seismic inplane forces

    I am conducting a reference design of masonry infill panels inside a concrete frame which has been designed to seismic design category B. Masonry infill panels must be detailed in such a way that it will not perform as a shear wall under ground seismic movement. This might be achieved by...
  7. Oversee

    Grond bearing slab and flexible pavement to American codes

    I am currently designing a ground bearing slab as ring roads of an arena. Based on a rule of thumb, 250mm deep concrete slab resting on 150mm deep graded sub-base aggregate will be capable of withstanding a live load up to 15kPa (315lbf/ft2) and a maximum axle load up to 8.5 tonnes in the UK...
  8. Oversee

    two-way slab design to ACI318-08

    I recently started to use ACI318 to design two-way slabs (with and without beams). I got two questions and I will be grateful if I can obtain some help. 1) Calculate the total static moments in the long and short directions (clause 13.6.2.2). This will give a smaller value in short direction...
  9. Oversee

    work examples of footings in biaxial bending to ACI 318

    Are there any work examples of pad footing design to resist biaxial bending based on ACI 318? I only found some simple examples from a number of textbooks. I wish to thank you all in advance!
  10. Oversee

    Special concrete moment frame

    We are designing a concrete building to SDC C (IBC 2003). From Table R21.1.1 of ACI 318, an intermediate moment frame system is expected. This allows the use of two-way slabs without beams in Cl 21.3.6. My question is: will it be acceptable to use concrete shear walls as the only...