Good Day all,
Can anybody have a look on the attached file page#22 and share please give some comments on this:
1- Firstly, I have checked the user guide of PVElite and found that for external pressure it takes 15psig (103.42kPa) whereas in the calcs shown on pg22 attached they have also added...
Hi all
In UCS-79 the formula is
% extreme fibre elongation = 75t/Rf (1-Rf/Ro)
now i have an elliptical head 2:1 D=3500mm h=875mm K=1 and for corrosion case D=3506mm, h=878mm and K=.998
Now I cant figure out where do I get this Rf and Ro to find the percentage elongation which is comming out...
Good Day,