Just a clarification regarding unreinforced openings in ASME VIII div. 2 subsequent to Ed. 2007.
Until Ed. 2004, AD-510 allowed for unreinforced openings for hole diameters less than 2" (50 mm).
Starting from Ed. 2007 unreinforced openings seem to be no longer covered, even if unreinforced...
Hi everybody
I'm to perform stress analysis by FE of some details of a pressure vessel in VIII div. 2 in this way:
1. Thermal analysis -> temp map.
2. Mech analysis for primary stress: temp map from step 1 + mech loads giving primary stress (engineer judgment...). To not introduce thermal...