I am not sure if this is the right forum to ask this question but anyhow, this is my question. In the horizontal (building) architectural/MEP engineering world, who is responsible for identifying and relocating underground utilities that fall under the footprint of a new building. For example...
I am not sure if this is the right forum to ask this question but anyhow, this is my question. In the horizontal (building) architectural/MEP engineering world who is responsible for identifying and relocating underground utilities that fall under the footprint of a new building. For example...
I am working on design-replacement of two older heating water boilers with two new condensing boilers- 3,300 MBH each. One of my colleagues mentioned that during summer we can use the heating water out of these boilers and preheat domestic water via a heat exchanger. Does this have any energy...
I have a client who asked me to prepare the MEP construction document for an ice rink. I would like to know what the main design requirements are, especially on mechanical side- such as codes, standards, etc. Does the mechanical engineer usually design the ice rink itself or is a third party...
I hope this is the right forum to post this. I am trying to find projects for a small MEP engineering firm. So far I have found out that the most effective way is to schmooze up to architects since owner prefer dealing with one firm (mainly an architectural firm.) Obviously, finding the...
I am working on a project in Dallas, Texas. The owner wants to combine two existing suites in a shopping plaza and make them one large suite. I need to know what approach to take to combine the electric and gas meters.
I am working on bathrooms renovation at an existing assisted living building in Texas. We want to route the exhaust duct through the outside walls. The question is whether NBC and NFPA codes allow that. Are perimeter walls in such buildings fire rated? If they are, then can we penetrate them...
I am working on bathrooms renovation at an existing assisted living building in Texas. We want to route the exhaust duct through the outside walls. The question is whether NBC and NFPA codes allow that. Are perimeter walls in such buildings fire rated? If they are, then can we penetrate them...
I have a specific question regarding control of SZ VAV systems. I know once the space temperature is satisfied, we need to ramp down the fan and modulate (close) the CHW vale to maintain DAT (specially for humidity control purposes,) but how exactly should the sequence of operation be for...
Does anyone know a website or have any tips on writing "introducing our company" emails to architects? How can I word the email to get them to at least give us a meeting?
What is the recommended temperature and RH for Libraries in K-12 schools.
ASHRAE HVAC Application handbook- 2011, chapter 7 says:
" To avoid growth of mold and mildew, a dew point above –1°C (33.8 F) and maximum of 55% rh are recommended.
Does this mean we can not have a temperature of 72 F...
I am designing a warehouse (ventilation, heating, etc.) in Dallas, Texas. Owner is a used car dealer and stores cars in this 20,000 sq.ft space. There is a prefabricated paint booth in the warehouse. There are 3 existing exhaust fans, 12000 cfm each.
What are the related codes, standards and...
I am a mechanical engineer and live in Dallas, Texas area. I am looking for a electrical system training course that is offered for non electrical engineers, mainly focuses on design of electrical distribution systems in industrial and commercial buildings, including service to all types of...
I am the engineer of record and project manager for MEP renovation at a school. We are in CA phase right now. Owner was supposed to have third party commissioning done on this project but I believe they are not going to hire a commissioning team and save the money. My question is, how...
I am a mechanical engineer and live in Dallas, Texas area. I am looking for electrical system training courses that are offered for non electrical engineers in this area? University of Wisconsin in Madison offers great courses but it's too costly for me to travel and stay there for a few days.
I am working on HVAC design of a office-warehouse. There is a janitor closet that opens to the warehouse, about 35 sq.ft. Is there any code requirements for ventilation of this closet? I know ASHARE 62.1 calls for 0.12 cfm/sq.ft. for a storage. In this case that's only 4 cfm. Plus, this is a...
Is there a standard or code required condensate drain line sizing procedure or chart? I have charts from different manufacturers that I have used for sizing these pipes but none of them say where they got the information from.
I have looked up IMC and IBC but did not see any information.
I have designed a chilled water system for a HVAC renovation of a school that has existing chilled water system. Classrooms used to have unit ventilators and I recommended to replace them with new ones. One of the mechanical contractors that are also engineering compnay has made a comment as...
I am specifying air handling units with chilled/hot water coils, VFD supply and exhaust fans, single zone, full economizer mode. Project is a school in Dallas, Texas. What are your opinions on heating coil in preheat vs. reheat position, draw thru vs. blow thru fan location, and other thoughts...