  1. sanshu1111

    Embrittlement of Duplex Stainless Steel (UNS 31803)

    One of our facility is operating under thermal cycle with temperature raging from 60 Dec C to 260 Dec C. After operating it for appx 5 years, we found some cracks on our piping system (flange and flange to elbow weld joint/ HAZ) which is in DSS UNS 31803 construction. We send this piping...
  2. sanshu1111

    Pass partition weld for Plug header type air cooler as per ISO 13705

    Not sure if I am reading it correctly as to why a full penetration weld joint preparation is required for the seal weld? In addition, seal weld from both the sides will not be possible if the air cooler is multi pass with more than one pass partition plates on the header or have stiffener...
  3. sanshu1111

    Erosion of desanding liners

    Dear all, We are facing severe erosion problems on desnding liners installed on produced water system. These desanding liners are of DSS (UNS 31803)and a part of multicyclone desanding vessel. We can understand some erosion on the liners due to sand but the rate at which erosion is taking...
  4. sanshu1111

    Requirement of test coupon as per UCS 85

    Heads are cold formed using normalized plates (P No 1, Group 1. Heads are subsequently normalized after cold forming. Do we need test coupon to represent normalizing after forming as per the requirement of UCS 85 (f)? Any idea if the below interpretation is still applicable as the vessel...
  5. sanshu1111

    Fatigue evaluation of stacked heat exchanger

    We have stacked heat exchanger designed with ASME Sec VIII Div 1. Exchanger experiences Thermal cycle with inlet temperature varying from 41 Deg C - 260 Deg C every hour. Fatigue evaluation for the exchanger was therefore requested as per ASME Sec VIII Div II. Heat exchanger vendor is carring...
  6. sanshu1111

    SA 516 Gr 70, Tempering Temperature

    Recently I came across some SA 516 Gr 70 NACT(nornalized + Accelerated cooled + tempered) plates from some reputed mill where tempering temperature is indicated as 590 Deg in MTC. As per SA 516 Gr 70, section 5.4 If approved by the purchaser, cooling rates faster than those obtained by cooling...