Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: MSEdesigns
  • Content: Threads
  • Order by date
  1. MSEdesigns

    Is it wise to use Geogrid and Soil-Cement?

    I have a project where the owner is proposing to use a soil-cement mix in the reinforced zone of a bridge abutment. The reinforcement options are HDPE, PET or hot dip galvanized strips. I have been advised by a local distributor of the PET geogrids that the cement alkalinity will damage the...
  2. MSEdesigns

    Geofoam at SRW reinforced zone

    What should be the parameters (internal friction angle and cohesion)for Geofoam. I will like to evaluate using geofoam in a SRW but don't know where to obtain these values. The local EPS supplier does not have any idea. They could only give me the density which was about 1.1 pcf and the...
  3. MSEdesigns

    Best compaction specification for MSE Walls

    Which Compaction method is best suitable for specifying the compaction requirements on a Segmental retaining wall reinforced with poliester geogrids. Material specified for the reinforced zone is A-2-4 or better.
  4. MSEdesigns

    Organic Content on A-1-a

    According to AASHTO T 267 test method, the organic content obtained is for the portion finer than sieve No. 10. Tipically the portion finer than sieve No.10 is less than 10 percent of the whole A-1-a sample. If I start with 1500 grams of A-1-a sample and end up with only 100 grams for the...
  5. MSEdesigns

    Organic content on fill for reinforced soil walls

    Can someone explain why AASHTO describes a maximum of 1% organic content as part of soil aggresiveness on soils to be used as reinforced backfill for extensible reinforcement, but when describing the soil aggresiveness for inextensible reinforcement, it does not mention the organic content at all?
  6. MSEdesigns

    best protection for HDG steel welds

    We had some problems and now have to weld the hot dip galvanized steel reinforcement used in a Segmental Retaining Wall. These reinforcements are made of steel rods about 5/8" diameter down to 3/8". They will be buried in granular material, probably 3/4" aggregate down to a...
  7. MSEdesigns

    SRW Maximum height record on one single tier

    We have done a one tier near vertical wall, 65 feet height and will like to know if any of you know of a higher segmental retaining wall. This was done with KeySystem units and steel reinforcements and is located in Puerto Rico. Work was completed on February 2002. Please let me know your...