Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: MrBTU
  • Content: Threads
  • Order by date
  1. MrBTU

    Heat Exchanger Drying

    Hello, Last year DK44 created a thread regarding drying of heat exchangers after fabrication and hydrotest (thread794-436465). I have this requirement on a job I am currently quoting. I would like to know the solution that was used and any suggestions. My requirement is 10 ppm of water. My...
  2. MrBTU

    Indian Engineering Firms

    Has anyone had any experience with outsourcing from the US, pressure vessel and / or shell and tube heat exchanger engineering to India?
  3. MrBTU

    Min Thickness at bottom of blind tapped hole

    My machine shop drilled too deep on some blind tapped holes, so that only .15" of thickness is remaining on the flange at the bottom of the hole (flg thickness is 1.5") They want to know if they can still use the flange. The only thing I can think of to justify this to my Code AI is to calc...
  4. MrBTU

    PWHT of Entire Heat Exchanger

    We have a type NEU complete carbon steel heat exchanger that needs to be post weld heat treated in it's entirety. I had planned to PWHT the shell and the bonnet, then welding the closing seams and do a local PWHT on them. The tube to tubesheet joints are strength welded. I have one person in...
  5. MrBTU

    Bypass relief in a heat exchanger

    Hello, We are designing over-pressure protection in an oil cooler, shell and tube heat exchanger to protect against high pressure drop during cold start up. This is to protect against damage to the baffles in the heat exchanger by supplying a relief valve around each baffle. We estimate that...
  6. MrBTU

    He Leak Test with Expl Clad Tubesheets

    We fabricated some heat exchangers with 90/10 CUNI tubes strength welded to 70/30 overlayed tubesheet. The units passed hydro fine, but they will not pass helium leak test - we are getting leakage through the strength weld (which we determined after bringing a guy in who could sniff each tube)...
  7. MrBTU

    Tubesheet Calcs

    Hello All, We are submitting a shell and tube heat exchanger design for PED for import into the EU. As such, it is designed to ASME Sect VIII Div 1, and submitted to a Notified Body for review. The tube pattern is such that the tubesheets do not fall under the scope of UHX (large untubed areas...
  8. MrBTU

    Russian GOST Requirements

    We are a manufacturer of shell and tube heat exchangers. For years, we have been supplying units to Russian GOST for import to Russia, and it was no big deal. We designed and manufactured to ASME Code, created a vessel dossier, shipped the unit, and we were done. Now, we're hearing that we...

Part and Inventory Search