  1. Pam60

    Selection of Ground Fault Detection method

    Hi gentleman, I have done it many times but need a bit of scientific explanation to the approach I have taken. I have a feeder entering a 2 MVA 13.8 kV transformer stepping it down to 4.16 kV Secondary which is resistance grounded with ground fault limited to 10 A NGR. I need to have a...
  2. Pam60

    Moisture in Circuit breaker/ D20 RTU

    Hi All, I have two completely unrelated questions and would appreciate your input. Ist topic is D20RTU and Second topic is AEG Vacuum type 38 kV outside metal class enclosed moisture isssue. Q#1 A) What would be the purpose of a test relay in old Datrac GE RTU ? B) My setup has...
  3. Pam60

    GE Electromechanical Relay

    Hi, I am sure you have seen it and done it all. I am not used to electromechanical relays and had my first encounter with them recently. I have a GE PJC32 relay http://www.gedigitalenergy.com/app/ViewFiles.aspx?prod=pjc&type=3 It is a instantenous relay with a curve charc. Customer has a...
  4. Pam60

    Cost Estimate

    Hi... Thanks for your earlier valuable suggestions. A new entry into my work is to estimate cost involved in retrofiting medium voltage 13.8 kV oil breakers with vacuum breakers. Could you kindly advise me where I can find construction cost estimates for utility environment. Thanks
  5. Pam60

    Phase Connection

    Hi Jghrist, In one of the last posts, you had commented "Keep in mind that if you have R-Y-B East to West for a DYn1 transformer facing North and R-Y-B East to West for a DYn1 transformer facing South, you will have a 60° phase difference in the secondaries and you won't be able to get the...
  6. Pam60

    Relay Logic

    Hi All, I just started a new position at a intermediate level in a electric utility. To my surprise the environment is completely different than I expected, it is probably more cold hearted than a consulting environment but that is besides the point now I just have to deal with it for a better...
  7. Pam60

    Substation Battery Charger

    Hi, I am supposed to work on a substation battery charger schematic and am working on getting some basic conceptual info. In this system, when station service transformer supply is avilable, the recifier will supply the DC panel but as soon as the AC supply will be off, the batteries will...