dear all,
does anyone has experience with the new piping systems like for example the geberit mapress system for industrial installations?
thanks for the reply!
kind regards
dear all,
we have a vacuum problem in a dimethylphtalate/water-methanol stripping column. after a washing section the mixture with aprox 2% water/methanol is entering the stripping column at about 130°C.
a vacuum unit (Nash) should keep the column at 50mbara using 3barg steam. we have no...
Dear all,
We hava about 150m³ of ethanol with 10% water that we need to dry so we can re-use it in our process.
what would be the most economic and easy way of doing this. We were thinking about a membrane system or use zeolite.
Anyone has experience? Are there rental systems for this...
Dear All,
We have a deposit problem in our thermal oil system (150m³) It is a two temperature system with a heat exchanger heating the oil to 170°C and a cold loop with a temperature of 70°C. Heating is with a steam shell and tube exchanger, cooling is done in a 200m² air cooler.
Since long...
Hi,
We would like to replace our dP measurements for a venturi flow measurement. There are 4 measurement venturi's in a reaction zone measuring the air flow to 4 reactors. It is difficult to connect these new systems with our old DCS system.
Would the following be possible?
- a new dP...
Hi,
An energy study indicated that we could save 3-4% active power consumption by installing condensator banks near some of our biggest electric motors (range 35-110kWe).
the local cos phi is in the range of 0.60 - 0.85.
A company offerd us a capacitor banks to have a local cos phi of around...
Dear all,
We have a stripping colum for stripping alcohol and water out of phthalates. It's a two section column with a steam ejector (500kg/u) between the two sections to reach a vacuum of 10mbara in the bottom and a serie of three steam ejectors using 8bar steam care for the vacuum. The top...
Dear all,
recently our boiler feedwater was contaminated with a large quantity of bio diesel and vegetable oil.
The pH dropped from 9,5 to 4,5 and the purge water was a milk like substance. We do not have a good idea on the quantity of bio diesel and vegetable oil that came in the feedwater...
Hi,
I have a question about the power factor of a 4500kVA (rated power) syncronous generator.
The generator has the following characteristics:
4500kVA rated power
0,8 rated power factor
6,3kV rated voltage
50Hz rated frequency
This installation will be used for power production using a steam...
We are facing severe corrosion problems on the wall of 5x5m vent gas duct before an oxidaton catalyst. In this duct one natural gas burner is installed to preheat the air going to the catalyst during startup. The material is HII steel welded on a structure made of metal beams. The sheets are...
Hi,
We need to make a selection for our new boiler feedwater pump. The pump is a 750m (75bar) high pressure pump working at different flow rates.
20m³/h for 2000h/y
40m³/h for 3000h/y
60m³/h for 3000h/y
the pump is stopped aprox 20 times a year.
We got several offers with different designs...
Hello,
I'm investigating the posibilities to burn torrefied biomass in a classical boxer fired PC boiler. the main aspects we want to investigate are:
- explosion safety/fire in the coal mills when processing torrefied biomass. An assesment of the risk of milling this material.
- combustion...