In ITN I foud stabilization after annealing and before aging.
Stabilization
fixture introduction in to the furnace at a temperature not higher than 300 °C, ris e
up to 850 °C, hold for 2 hours , cooling in still air (till T<200°C) and subse quent
cooling in water fo r 2 hours t o guarantee...