    Outdoor air for Brewery

    Hello, I am looking for the outdoor air rate required for a brewery project, ASHRAE 62 refers to ACGIH, ACGIH says the outdoor air rate must be as ASHRAE, any supported advise and thanks in advance
  2. 317069

    Space cfm calculation in a residential house

    Hello, A house heating load as following (the numbers are only as example): - Winter outside/inside temperature design : 0F/70F - Supply air temperature: 120F - space load (envelop + infiltration): 60000 Btu/hr - OA ventilation requirement 100 cfm, (7560 Btu/hr) the question is about air flow...
  3. 317069

    for a regular house HVAC system (Fu

    for a regular house HVAC system (Furnace and AC unit), is the external static pressure the same in both heating and cooling modes? in my understanding the answer is No. I mean can we say the furnace fan is 1600 cfm @ 0.5" for heating and 1600 cfm @0.5" for cooling.
  4. 317069

    Return air plenum

    In typical office space with suspended ceiling tiles, do we consider the 2 feet return air plenum as a part of the zone in regard to the zone cfm calculation? what would happen if we considered it or we do not.?
  5. 317069

    VAV box minimum postion and ventilation equirments

    How do we consider the VAV box minimum position.? I am reading ASHRAE 62, 2007, multiple zone calculation and trying to apply on an example from my imagination. three zones, A, B , and C, served by three VAV boxes. let us say all efficiencies mentioned in the standard equal to 1, Supply air...
  6. 317069

    Economizer and ASHRAE 90.1

    A commercial space (small store for example) with 8 tones cooling load, if we serve it with 8 tone rooftop unit then we need an economizer as per ASHRAE 90.1, do we still need economizer if we serve it with two 4 tones rooftop units, each one has its own discharge duct system? the question is...
  7. 317069

    Ventilation rate, person and area

    Hello, 1- a 1000sq.ft of office space with 4 occupants needs [(5*4)+(1000*0.06)]= 80 cfm of outdoor air. 2- a 2000sq.ft of office space with 4 occupants needs [(5*4)+(2000*0.06)]= 140 cfm of outdoor air. both spaces have the same height, same everything except the area. I think the air in the...
  8. 317069

    ASHRAE 62-2001

    ASHRAE 62-2001, table 2 says 20 cfm/person in conference room, while table 6.1 says 6 cfm/person and both are for the same occupancy (50 persne/1000 sq.feet) which one we have to use?
  9. 317069

    Commercial Hood's cfm

    Three commerical kitchen equipments A, B, and C are under a hood, all of them have the same dimensions, say: 3'x 24" so our hood would be 10'x36"x24". equipment A needs 300 cfm/ft equipment B needs 200 cfm/ft equipment C needs 100 cfm/ft 1) what the total hood exhaust would be? is it 10'x300 =...
  10. 317069

    Question about economizer control

    A standard 2 ton RTU with air side economizer serves internal zone which needs cooling all year. During the winter, the unit is on cooling mode, ambient is about 0 F, will the economizer cycle on and open 100% fresh air in this conditions?. if yes what about the supply air temperature?
  11. 317069

    Question

    Hello all Two zones A&B have the same occupancy, let say 10 persons each, the load calculation told us that zone A needs 600 cfm, Zone B needs 400 cfm fore example, and both of them need 150 cfm of fresh air each for ventilation. Now total cfm is 1000 cfm, fresh air is 300 cfm which means 30%...
  12. 317069

    Question

    Hello all if we have a 150 feet uninsulated duct connected to air handler. is there rule of thumb to put reheat coils. thank you
  13. 317069

    fin tube system

    Hello all I have general question can we estimat the capacity of a fin tube provided by hot water from a water heater(not from a heating boiler)the tube length is about 8 feet Regards
  14. 317069

    laundry room in apartment building

    Hello All I have 7 gas dryers in laundry room in small apartment building. - is ther any special recomendations to connect thier lent vent to a common exhaust duct - is ther any special recomoendation for this laundry room. Thank you all
  15. 317069

    questions

    Hello all I have questions: 1- is it a good idea to use a perforated spiral duct into an ofice space 2- any rul of thumb to select a water pump for a boiler Thanks
  16. 317069

    pressurizing a space

    Hello All how can we pressurize a space with typical HVAC system (a unit, supply duct, return duct,and HRV unit).? I mean if we have 1000 cfm of supply air that mean there will be 1000 cfm entering the unit fan in order to get a 1000 cfm from this fan.
  17. 317069

    heating coil capacity

    Hello all I have a question: I am traying to select an AHU ( hot water for heating, DX for cooling) for an application. For the cooling side th unit is ok but, for the heating side the capacity of the coil with the nominal water flow mentioned in the catalog is much higher than my requirment...
  18. 317069

    tall building

    Hello Any advise about a book or reference link shows a detailed example of HVAC for a tall or high rise building. Thanks
  19. 317069

    register place

    Hello All What would happen if we placed a side wall supply air register (or grill) above a window and blow the air toward inside the space instead of flashing the window by supply air? Thank you
  20. 317069

    Equipment selection

    Hello all When we select equipment, always the available value dose not match the load calculations, sensible load could be in range, but latent load is not, or visa-versa. the sensible load would be ok in range of up to 5 or 6% less than calculated, but waht about the recomended range of the...