I have a 5.000 +.060 -.000 high forging with a oof of.060
my problem is that the top surface has some waviness and there are low areas on both faces not across from each other
so I placed part on a surface plate measured the top face with a height gage found the lowest spot, then subtracted the...
I have a large forging (36" ID). the tol. is 36.000 +/-.060
when measured with a vernier the id max diameter is .060 smaller than what our CMM max diamater. caused from the part being .090 O.O.R.
when inspected on CMM and graph the results the actual shape of the part is shaped like a three leaf...