  1. ebarba

    Mysteriously increased natural frequency in structure

    Hello all, a customer complained one of our vibrating-table machines was not working. These are reactive machines - i.e. two-degree-of-freedom systems - where the vibrating table is the second DOF and sits on springs (circular steel bars). The bars are attached to a structure (first DOF) where...
  2. ebarba

    Fracture location in large cast iron part

    Hi, We’re going to attempt to locate a suspected fracture in a large cast iron machine part. The part is a shallow, hollow cylinder with vertical axis, about 400 mm tall and 1500 mm in diameter. To access the inner part of the cylinder there are a number of inspection doors about 120 mm día in...
  3. ebarba

    6 Permanent Magnet AC motors driven by one VFD

    Hi all, because space constraints we are considering to drive six 4 kW, 400 V identical 10-pole, PM AC, sensorless motors with only one VFD. The applied torque on each of the six motors is NOT the same and varies with time. I understand the logic that the VFD will fail to determine the...
  4. ebarba

    Enclosure noise attenuation assessment

    Greetings, We must assess the noise attenuation of a sound enclosure designed to contain a 135 dBA noise source with a reduction of 50 dB. The noise source is not yet active and won't be until late September, but an assessment of the noise enclosure is necessary for payment purposes. A...
  5. ebarba

    starting 100 kW AC motor using inductance

    Hi all, is there a way to use a 3-phase inductance to start an AC motor? The whole picture: the motor is in reality a 110 kW asynchronous 3-phase generator (400 V, delta connected, 50 Hz), moved by an internal combustion engine. Because the generator is SO massive it tolls the engine starter...
  6. ebarba

    Intake temperature vs efficiency

    Hi! Which one of the following two intake manifold conditions will lead to better efficiency, on a spark-ignited engine? Can someone say what is the ballpark efficiency increase between the best and worst condition? A) 1.5 bar(a) pressure and 100ºC B) 1.5 bar(a) pressure and 50ºC Both...
  7. ebarba

    Noise enclosure for supersonic nozzle

    Hi all, we have to build an enclosure to attenuate an SPL of 137 dBA @ 6 ft, coming from a high-temp supersonic nozzle. A double-walled enclosure with all due precautions and acoustic tricks should provide the 55 dBA attenuation, but we need to reach 60 dBA attenuation and I'm especially...
  8. ebarba

    Is knocking/detonation possible in gaseous fuel fired Otto engine?

    Hi all! We're running an 8.0L turbocharged engine on wood gas to drive a stationary electric generator, rated 100 kW. Wood gas composition is essentially: 20% H2 20% CO 5% CH4 55% N2 We are experiencing loud "clanking" noises coming from the engine when we approach rated power, the conditions...
  9. ebarba

    Poor power factor - induction generator

    Hi all, We're getting a much lower power factor than anticipated on a 100 kW asynchronous generator intended for 100% power export to the grid. It is connected via a dedicated line that serves only this generator and it's auxiliary systems (about 5 kW worth of 3 phase motors). This is a follow...
  10. ebarba

    Maximum vibration on 100 kW DC motor

    Hello all, A 100 kW DC motor has been moved from its original place (anchored to the floor) on board a centrifuge which now is mounted on air springs and vibrates. The motor runs at 1000 rpm the transmission lowers the load speed to 330 RPM. RMS vibration velocity is 1.4 in/s. The motor is not...
  11. ebarba

    100% capacitive reactive power exported to grid by an induction (asynchronous) generator

    Hi all, we are starting up a 100 kW power plant meant to export 100% power to the grid. The plant consists of an internal combustion engine driving an asynchronous (induction) generator. The generator has a rated power factor of 0,85. After a short test (50% rated power, about 10 minutes), the...
  12. ebarba

    Natural gas fired engines driving gensets - life expectancy

    Hello All, A couple of gensets will be operated at a constant load for 1500 hours a year on a 16h/day scheme. Engines are GM industrial powertrain Vortec 5.7L (350 cu.in), 8.1L (496 cu.in) and 8.1LT (496 cu.in, turbocharged), fired with Natural Gas and load is about 80%, 65% and 75% of standby...
  13. ebarba

    Averaging: RMS vs Vector

    Hello all, I'm trying to assess vibration attenuation spectrum of a flexible suspension for an automated punching machine. My instrumental setup is made of two accelerometers, one mounted on the machine and the other one on the floor nearby the machine. The excitation comes from the machine...
  14. ebarba

    Books on silencers and mufflers

    Hello everybody! I'm looking for some good book(s) on muffler and silencer design. I'm interested in dissipative, reactive and hybrid silencers for gases ranging from air to combustion exausts. Is there any "famous" title everybody working in this field should have over his favorite shelf...