  1. GearsNsparks

    Rectangular Connection Element: Interaction Equation Valid for Compressive Loads?

    Looking at the interaction equation for rectangular connecting elements in AISC 360 - Equation 9-1: Mr/Mc + (Pr/Pc)^2 + (Vr/Vc)^4 <= 1.0 Is this equation valid for axial compression loads Pr/Pc)?
  2. GearsNsparks

    Overstrength and Nonbuilding Structures Not Similar to Buildings

    I'm trying to figure out where (and if) Omega gets used when designing steel members and connections for non building structures not similar to buildings (Table 15.4-2). Does it only show up in the foundation design? A couple items for tanks and vessels are called out for section 15.7.3.a, but...
  3. GearsNsparks

    VFD and Locked Rotor Torque

    Howdy, If a 20HP NEMA B AC induction motor has a locked rotor torque of 200% of full load torque, would a typical VFD be capable of developing that locked rotor torque condition at start up? The current is 600% of full load current at start up according to the speed vs current curve chart. Is...
  4. GearsNsparks

    Steel Connection Design: Gap Between End of Beam and Column Flange

    Howdy, I'm looking at a bracing connection for some existing mining equipment structures. There is a nominal gap of 1/2" between the end of the beams and the connection to the flange of the column. Is this a common practice? Is it intended to help with manufacturability (getting the columns...
  5. GearsNsparks

    Geometrically symmetric struts with balanced vs. unbalanced loads on a column

    1. When designing columns with symmetric struts attached (see attachment) and assuming the tributary span A = tributary span B, do engineers still design for a shear load imbalance on the column due to fabrication imperfections? 2. When tributary span A > span B, is it reasonable to assume...
  6. GearsNsparks

    Comparing Brace Configurations

    I'm looking at two brace configurations and I don't think one has greater capacity than the other. See the attachment: Is there a reason why someone would design for style A instead of B? Does it come down to fabrication or...
  7. GearsNsparks

    Connecting to Wide Flange Column Flanges

    When modeling a member connection to the flange of wide flange columns, do people typically make a rigid link perpendicular to the column and half the column depth to impart the moment do to connection eccentricity?
  8. GearsNsparks

    AISC Compression of Members Based on Gross Area vs Net

    Is there literature in the AISC commentary explaining why compressive strength capacities (equation E3-1) are based on gross area rather than net area? I think if I turned some angle into swiss cheese by placing bolt holes in it, the compressive strength should be less than without bolt holes...
  9. GearsNsparks

    Locating Strut Attachment Point to Bents

    Is it a mistake to place the strut attachment points on the bents of a column as shown in the image instead of attaching to the beam with the vertical braces? It seams like attaching to the vertical brace beam would minimize bending on the column but induce torsion in the web of the column. On...
  10. GearsNsparks

    Mining Conveyors... Who Typically Designs Them

    Who typically designs mining conveyors and hoppers? 1. Civil Engineers 2. Civil Engineers w/ PE 3. Mechanical Engineers 4. Mechanical Engineers w/ PE 5. CAD Technicians I'm trying to figure out if these are typically engineered, and if so, by whom. Are PE stamps...
  11. GearsNsparks

    Delrin AF Rollers Squeaking

    I have 1/4" OD x 0.1258 +0.0003/-0.0003" ID X 1.00" long rollers (material spec is Delrin AF) that are attached to a peristaltic pump head via 0.1250 +.0002/-0.0000". Occasionally (1 out of 20) roller+dowel pin combinations will provide me with a periodic chirp/squeak as the pump head turns...
  12. GearsNsparks

    Governing Code or Standard for Diesel Generator Exhaust Piping?

    What is the governing code or standard for diesel generator exhaust piping? The application would be central utility plants (hospitals) with 2.5MW output.
  13. GearsNsparks

    Governing Code or Standard for Diesel Generator Exhaust Piping?

    Is there a governing code or standard for the design of diesel generator exhaust piping?