  1. 300redbeard

    Flexible Diaphragm for Sun Shade Shelter

    I have a background in designing PEB's and mini storage light gauge steel structures. In my experience I have used either diagonal rods or diagonal flat strap bracing for my flexible diaphragms when using steel roof decking that is NOT shear rated: typical standing seam roof. I'm reviewing...
  2. 300redbeard

    Machine Bolts vs. Grade A307

    I know machine bolts come in various grades. On construction documents should 'machine bolts' call outs be referenced to comply with ASTM A307?
  3. 300redbeard

    Dowels from CMU wall to slab

    I'm performing a plan review. Example: 8" slab w/#3 bars @ 18" oc ea way & #4 dowels (from CMU wall) @ 24" oc. (obviously different spacing) Does this fly? I've typically always required/designed my slab steel and dowels to the same spacing for lapping together. I've always had the...
  4. 300redbeard

    Maximum Diaphragm Dimension

    IBC 2006 section 2305.2.3 gives ratios for maximum diaphragm dimensions for wooden structures. Is there a maximum diaphragm dimension for a roof diaphragm with VERCO steel deck attached to reinforced concrete shear walls? Thanks
  5. 300redbeard

    Anchor bolt diameter?

    Public Works Issue-21' tall abutment with 26' span I have an issue regarding anchor bolt diameters. AISC table J3.3 states for 1/2" dia. holes: std-9/16", oversize-5/8" and long slot- 9/16"x1 1/4" respectively. I have a bearing plate on a pedestrian bridge that the fixed end has 3/4" dia...
  6. 300redbeard

    Modular Building Seismic Design

    If a modular building (trailer) is on 3 ft piers/jacks, should the base shear (at floor level) be multiplied by the pier height for an applied moment to be restrained by seismic holdowns? I've been reviewing calculations from multiple engineers/companies and they are not accounting for the pier...
  7. 300redbeard

    Earthquake Restraint Bracing System

    Modular Buildings supported by piers are not specifically called out in the IBC 2006 and ASCE 7-05. In southern California, San Diego, San Bernardino and Riverside counties all require Earthquake Restraint Bracing System (ERBS). I work on DOD base and have an issue with a contractor installing...
  8. 300redbeard

    Assumed Area of Steel In Existing Concrete Beam

    I'm doing a remodel on an existing structure. It has a 14" x 21" concrete beam spanning 18'. The building was built in the early 1950's. I know that was when working stress design (WSD) was being used. I don't have as built drawings, so I'm trying to figure out the minimum area of steel based on...