Hi
For a HV single conductor cable passing thru foundation with rebars around ,how much should be the clreance from rebar to cable to make sure that induced heating will not damage the PVC conduit and eventually the cable ?
Thanks
Hi every one
A EHV cable was cut and left exposed to High moisture and water( no cap at either end of cut cable ) , i know about effects of moisture on cable specially on insulation deterioration also i know there are methods to dry out MV cable such as using N3 , To make the long story short...
Ladies and Gentlemen
As We know Partial discharges occur when the local electrical field intensity exceeds the dielectric strength of the dielectric involved, resulting in localized ionization and breakdown , i was wondering how current will effect PD ?
Hi
I am looking for a rubber gasket , 9mm and 60 shore .how can calculate the tension and pressure if i squeeze that inside a clamp to protect an electrical cable? basically i want to see if its possible to calculate the force applied from gasket to cable .
Thanks
Gents
I am trying to design a support structure for a EHV line, is there a method to calculate the force appears on cable due to ? Cable manufacturer has some recommendations based on practical experiences I want to know if its possible to calculate by theoretical means or not .
Thanks
Hi Ladies and Gents
happy Holidays
Can please somebody explain how per unit calculation will be done for two transformers in parallel ? one is off turn ratio .
Thanks
Hi Gents
What are the requirements for cable hipot test ? when a cable should be hipot tested ?is that true that after determination of a cable (specially MV cable)to terminate that again it must be hipot tested ? is there any code regarding that ?
Thanks .
Gentelmen
Two generators are feeding the same line through two different transformers and one common switchyard breaker, if I open the Breaker for that line both Gens will be off the grid and technically they should trip their 52G breakers because of either overspend or over frequency, but as...
Hello Gentlemen
Can you please explain me why we usually have Positive MVAR for Gas turbines and Negative ones for Steam turbine? Is it because of different excitation system?
Thanks in Advance.
Hello guys
My VFD output Voltage, Current and frequency are fluctuating (what i show on VFD LCD), is that normal ? if not what can be the reason?any thing i can do?
thanks in Advance.
Hi
Can any body explain me how does sensorless control mode regulate the flux?also why they say not to use a VFD with(Base Volt/Base Freq) > (Nominal Volt/ Nominal Freq )?
thanks in advance.