Can anyone give me some input on FEA with ANSYS to fix a potential case of conflict I'm in between?
From a Contractor my Company got an equipment, a quite slender header with a complicate geometry. The Contractor is responsible both for design and construction. The equipment is intended for a...
Dear all
I'm discussing with a supplier about this fact: in presence of a very slender and light thickness pipe header 8" O.D., thk 8.18 mm, 3.8 m length,with four 6" nozzles, designed at 42 bar (g)/170 °C, mat. SB 425 UNS 08825 (See the link to understand geometry) I'm asking for the...
Hi Gents
I have in front of me n°6 fin fan cooler ( three bays / two per bay ) in sour service (high H2S contents), design 120 bars / 115°C, UNS N08825 ASME VIII div.2.