Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: scanf1027
  • Content: Threads
  • Order by date
  1. scanf1027

    Continuous Beam w/Cantilever End Spans

    I'm modeling a continuous beam that has 5 spans and the end spans are cantilevers. When all of the spans are equal, the moment at the first supports from the ends from Risa are correct. That is they match the moments calculated using structural analysis; w(l^2)/2. When the end spans don't equal...
  2. scanf1027

    Conspan Deflection

    I am using Bentley's Conspan to design a voided slab superstructure. I am trying to find out why the Service I self-weight deflection doesn't match the deflection due to the self-weight load case, or my hand calculation.'there should be no factors applied for Service I. I have stripped off all...
  3. scanf1027

    Architectural Stainless Fabricators

    I am looking for a very good shop capable of high end fabrication of stainless steel architectural metal work. Five-axis cnc type of work. Any suggestions on where to look? Thanks
  4. scanf1027

    Software for Analyzing Steel Rod Table Base

    I am analyzing a table for a friend that has a base made of 3/4" diam. steel bars, with a 1" thick glass top. The base consists of one piece of bar that has many 90 degree bends, and stability may be an issue. Risa 3D and other programs can do this, but I was wondering if there is software out...
  5. scanf1027

    Headed Anchor Rod Confinement Steel per ACI

    I am trying to understand the provisions of ACI Appendix D (318-08), specifically Section D.6.2.9 on anchor confinement reinforcing. To me, the code doesn't specifically state how to design the confinement steel, but states the steel must be developed in accordance with Chpt 12. I checked in...
  6. scanf1027

    Total Seismic Weight

    I am determining the base shear for a single story structure and someone told me that I shouldn't include the parallel wall weights in this. I also read in the Structural Engineering Reference Manual, 4th edition, Diaphragm Load Section that the seismic weight tributary to a diaphragm should not...
  7. scanf1027

    AISC Seismic Design Manual Ex 4.4

    I am designing OMF connections using the Seismic Design Manual, for an R > 3. The thing I'm confused about is the required shear. Section 11.2a of the Provisions states Vu or Va must be increased by the seismic load effect, E = 2[1.1RyMp]. Page 4-3 of the Manual shows the same value but in the...
  8. scanf1027

    NCMA CMU Lintel Values

    I've been designing some cmu lintels and some configurations I need are not in Table 4 of TEK 17-1B. I created a spreadsheet to design my lintels and checked it against the Table 4 values. What is strange is some Mresisting values match and others are off by a significant amount, say...
  9. scanf1027

    RAM SS Composite Beams

    Can someone tell me why RAM computes a negative moment capacity for a beam using the composite properties? I checked the documentation and it does use the composite properties if the moment isn't greater than 2x the positive moment. Unless I'm missing something, the code states that the...
  10. scanf1027

    Disconnected Node Mass

    I have a model with multiple diaphragms at different levels, but also at different locations in plan; it is an "L" shaped structure. With the various stories, I have columns that RAM treats as segmented at the different story locations. The problem is the little segmented column masses are not...
  11. scanf1027

    RAM SS Redundancy Factors

    I am using v11.2 and am having trouble with the redundancy factors for seismic analysis. I manually input the rho values as 1.0 in the load combination generator, as my project is SDC B. However, when I check the output it lists varying values of rho, typically 1.5. I checked the Manager Default...
  12. scanf1027

    H20 Truck Loading

    I am designing a below grade concrete culvert. My question may be dumb, but the way the IBC states to distribute the load seems unconservative. Also, IBC refers to AASHTO, but I thought AASHTO specified a 32 kip pt load. Essentially I'm modeling a 1' wide strip of my box culvert structure...
  13. scanf1027

    URM Wall Base Fixity

    I am modeling a structure with unreinforced brick masonry walls and concrete diaphram, with both axial and lateral applied loads. It is a narrow structure and I am trying to accurately determine the restraint of out-of-plane drift provided by the wall bases. I have to assume there is no dowels...
  14. scanf1027

    Rigid Baseplate?

    I am designing column baseplates using Risa Base (FE element software). I recently attended a webinar from Risa on this software. The presenter suggested not checking the "force baseplate to be rigid" box saying it may not be conservative. The anchor tension values you get from assuming rigid...
  15. scanf1027

    Outdoor Plaza Category

    I am working on a project where we have to analyze an existing outdoor plaza, that does not have vehicular loads. I'm not sure what category this falls within. I actually thing the appropriate code is the relatively new ASCE 31. Any suggestions?
  16. scanf1027

    Torsional Stresses

    I am trying to use the torsional stresses reported by Risa to compare to the AISC Design Guide #9 Example 5.1 for checking torsion. It seems the warping stresses reported by Risa are reverse of what I should be seeing at midspan. Risa shows the max warping stress (for top and bottom) at beam...
  17. scanf1027

    Meshing Wall/Slab Plates

    I have created a 3D model of a concrete structure and used plates for walls and slabs. I have had trouble when meshing a wall that is connected to a slab I already meshed. Using the auto mesh tool, Risa does not recognize the existing joints along the common edge and I have to go in and manually...
  18. scanf1027

    GMAW Pre-Qualified Welds

    I have a project where the special inspector flagged some welds because they were done with GMAW process. The welds are 3/16" vertical fillet welds. Is this procedure pre-qualified for this type of weld?