  1. gkandy

    ASTM Equivalent of European code

    What is the equivalent of S275JR in ASTM ? Is S275JR superior to ASTM A 36 ? Awaiting responses Regards Kandy
  2. gkandy

    Sulfur Storage

    We propose to install a chemical unit to handle approx 4MT of powder sulfur per day. We propose to receive sulfur in 50kg / 500 kg bags. Where can I get safety data on sulfur handling ? I will prefer a website reference . Is it necessary to have conductive flooring for the sulfur handling area
  3. gkandy

    Dimethyl foramide _ Safety /Storage/Price issues

    Hi all Does anybody have expereince in dealing with dimethyl foramide ( DMF ) . I am basically intetested in the safety and storage precautions ? Is it safe to handle in drums or unload the drums into a storage tank and then use it from there ? Our daily requirement will be about 340 kg. Who...
  4. gkandy

    Packing Line

    Hi all I am looking for a semi automatic/automatic packing machine suppliers for epoxy resins. The resins will be filled in tins of various sizes from 1/2 lit - 30 litres.. Could somebody give me any leads on potential suppliers in Europe / Middle East ? thanks in advance G.Kandaswami email ...
  5. gkandy

    Cation regeneration- H2SO4 or HCl

    Some cation beds are regenerated with sulfuric acid and some with HCl. Obviously it depends upon the type of resin structure and exchange . I would like to know 1 ) What is the criteria which decides whether one uses a H2SO4 or HCl regenerated bed ? 2 ) Which is the better option from resin...
  6. gkandy

    Waste water recovery

    We are having a problem in the disposal of waste regeneration water from our ion exchange resin system. Presently this water gets mixed with the cooling tower blowdown and and goes to aa neutalising pond where it is diluted , pH corrected before discharging into the municipal system. We are...
  7. gkandy

    Breather Valve

    Demineralised Water ( for Boiler Feed Service ) Tank and Sulfuric Acid ( 98% ) Tank are normally provided with Silica gel absorbers in their vent for moisture absorption ? Do we require any breather valves for prevention of vaccum? Is there any other option other than using inert gas to fill up...
  8. gkandy

    BOPP Machinery

    Require suggestions on suppliers who could provide a complete BOPP manufacturing line. Other than Mitsubishi and Bruckner of Germany. Thanks
  9. gkandy

    New Projects / Retrofits/ revamps

    I am looking for upcoming new projects , retrofits and revamps in process industries. I would like to know where I get the info. Web sites reference / magazines or any lead will be useful