Hi,
I am more electrical than mechanical, I have an application which need to be modified, the current machine checks for axial and radial runout on a crankshatf, specifically on something that is called time gear or time cogwheel (sorry but english is not my native language) the case is that...
Hi, I have a chaallenge of generate a microseconds delay in Visual Basic, I know how to generate delay on the order of milliseconds (see below) but is too long for my application. Does anyone know how to generate this microsecond delay on Visual Basic 6.0.
Thanks
JM
Hi there,
I have an application in which a crankshaft is manufactured, lately defects have been found on several pieces, the defect is less material as is suppose to be (i have some pics if someone need to take a look), I need to sense in some way to ensure that the piece is always...
Hi,
I am experimenting with a programmer for 24CXX type serial EEPROMs, I developed a programmer interface for the serial port (I don't want to use the parallel port which is a common preference) on the PC, I have tested this programmer using PONYPRO program and works just fine, the thing is...
Hi,
I have downloaded from the net a programmer that uses serial port from the PC, also i downloaded different applications to programm the serial EEPROM (in my case I am using a 24C01 (1K EPPROM) I am able to read and write using these programas which tells me that I aseembled my programmer...
Hi,
I have downloaded from the net a programmer that uses serial port from the PC, also i downloaded different applications to programm the serial EEPROM (in my case I am using a 24C01 (1K EPPROM) I am able to read and write using these programas which tells me that I aseembled my programmer...
Hi everyone,
I have an unusual application in wich I need one Output (OUT1) and two input signals (IN1 and IN2)in a circuit, the input signals will provide +V (+24V) or will be open (lead lifted not grounded) depending on certain conditions:
1. IN 1 = +V, when this happen a Step Up voltage...
Hi,
I am trying to connect a Laptop (Windows 2000 Professional) to a PC (Windows XP Professional) using a twisted pair cable a the ethernet cards on both, to configure I used on the laptop the following setup
I/P Address: 10.114.0.1
Subnet Mask: 255.255.255.0
And on the PC
I/P Address...
I am new to PLCs so please bare with me on this. I am trying to implement an small application using a Micrologix 1500, basically the operation of the machine is not complicated, but it requires a jogging control using two buttons START and STOP.
1. By pressing quickly two times the STOP...