  1. Keith1976

    Honeywell HC900 and ML50

    Dear All; I am supervising 2 sites within one factory. Site A: There are 5 compressors running with ABB inverters. The inverters have modbus RTU built-in. They are monitored and controlled by HC900 via modbus RTU communication. Site B: There are 2 compressors (stand-by) operating with Danfoss...
  2. Keith1976

    Danfoss softstarter MCD500

    Hi All; Does anyone have experience using the above softstarter? The marketing article said that it has learning capability to have smooth stop. Keith
  3. Keith1976

    Danfoss FC202 can not reach 50Hz output

    Hi All; I am using FC202-200kW to run a centrifuge pump (distribution pump). Since I only make use of the soft start and soft stop, I run the inverter in Hand mode and press the '+' button to reach 50Hz output. But the display show that the maximum is 47Hz and status is RAMPING, not RUNNING...
  4. Keith1976

    Touch screen panel for plotting

    Hi All; Does anyone have experience with Honeywell HC900+HCI touch screen? Can I plot historical value of an AI on HCI touch screen? Thanks, Keith
  5. Keith1976

    water leak detector

    Hi All; I tried looking for the same thread but ended up with the helium stuff. Most of the manufactures (RadCom, Gutermann) that produce underground water leak detector use noise corregulator principle. I would appreciate it very much if anybody can share his/her experience with me. I doubt...
  6. Keith1976

    water meter with accuray +-0.5%

    Dear All; Nowadays, the technology for water flow measurement is using Faraday's law (electromagnetic flowmeter) where the accuray can be +-0.25%. But the challenge is the cost. It is extremely expensive if we want to have size 1/2 inches for residential use. It is applicable and acceptable...
  7. Keith1976

    Wireless Modbus RTU

    Hi All; I need some input here. I am installing drives in pump stations. Station A is located 15 miles from station B(manager office). In Station A, there are 2 pumps with 2 drives (has modbus RTU built-in). At the moment there is no PLC orwhatsoever in station A. Station B is luxury. It has...
  8. Keith1976

    Modbus RTU in Danfoss FC202

    Hi All; I am trying to read the relay status in Danfoss FC202 parameter 16-71. How can I do this? Using word status or 03HEX command? I am a bit confused on the difference between STATUS WORD and reading DO status via 03HEX command? For example, if I want to know if there is alarm in the...