  1. maxibonne

    Run time error

    I have seperate folders all containing different Ansys runs on PC. Each folder contains all the files from 1 seperate run. I then backup my work and copy to external hardisk 'HD1'. I run Ansys accessing HD1 and all works fine. I then copy all the folders from HD1 to another external hardisk...
  2. maxibonne

    *get

    Hello everyone Is it possible to select a number of nodes, and then use *get, to obtain the respective node numbers? I have trouble finding this in the Help for *get. I then want to use another *get to get the UY disp of each node. Thanks maxibonne
  3. maxibonne

    Running batch mode

    Hi I would like to run multiple consecutive runs in Ansys. I am unfamiliar with DOS. I cannot understand the Help file: set ANSYS100_PRODUCT=ANE3FL set ANS_CONSEC=YES "C:\Program Files\Ansys Inc\V100\ANSYS\bin\intel \ansys100" -b -i vm1.dat -o vm1.out "C:\Program Files\Ansys...
  4. maxibonne

    Area colouring and numbering

    Hello everyone I am getting this very strange problem. I have a 3D model with a large number of Areas. In the middle of a /prep7, I switch on the Area numbering from the Menu, but upon 'aplot' 1) All areas are listed as A1 2) All areas are the same colour I did not join the areas together or...
  5. maxibonne

    local or global coordinates

    I am plotting a path, and then extracting the stresses acting along this path. My question is: Are these stresses that I extract given in local or in global coordinates? Many thanks
  6. maxibonne

    view all iterations of loop in output file

    I was wondering whether it is possible to output all the iterations of a *do loop in the output file? Currently my Ansys is set to only output the first iteration.. Is it possible to change? thanks
  7. maxibonne

    output *get

    Is it possible to store the results from a *get (*get,xposition,node,i,loc,x) other than use an array? I was thinking of something similar to 'store' which is used to store results using 'nsol'. Does it exist in Ansys? regards, maxibonne
  8. maxibonne

    time-history post processor

    I am trying to find the maximum value of temperature my nodes go through after a thermal solution. From the 'time-history' post processor I select 'Add data' and select a node. I cannot understand what's next. I have tried to type in TEMP in the first box on the calculator and then click on...
  9. maxibonne

    ramp or step input?

    In a static structural non-linear analysis, what difference is there between applying a load as a step or a ramp with 'kbc' in ansys ? Does it affect results? Max
  10. maxibonne

    ramp or step input?

    In a static structural non-linear analysis, what difference is there between applying a load as a step or a ramp with 'kbc' ? Does it affect results?
  11. maxibonne

    maximum nodal temperature

    I am doing a thermal analysis of a weld. Any ideas how I can get the maximum temperature reached by each node, in the path data? thanks
  12. maxibonne

    exporting data from ansys

    i would like to export data from a Path, into notepad. i can't find from the path operations menu which is the command. any help please?
  13. maxibonne

    mptemp

    I am using mptemp in my program several times, and sticking to the conditions stated in the help file, but ansys does not seem to want to accept it. I keep getting the error: 'Temperatures for material properties must be in ascending order. The MPTEMP command is ignored.' My...
  14. maxibonne

    ekill and ealive

    I am doing a structural analysis after performing a thermal analysis. In the structural solution I use the 'ldread' command in order to read in the nodal temperatures from the thermal solution. For the ldread, my solution converges up to the time when my elements are killed. At precisly the...
  15. maxibonne

    ldread

    I am doing a thermal stress analysis. Can anyone tell me how to control the number of iterations 1 ldread step does? (to read the nodal temperatures in the structural solution) Thanks